2864095 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2864095
Manufacturer:Phoenix Contact
Category:Electrical Measuring & Monitoring Instruments
Product Lifecycle:Active
Get a quick Quote!
MCR potiposition transducer for conversion of potentiometer positions into a standard analog signal, 0 Ω input... 100 Ω to 0 kΩ ... 100 kΩ
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2864095 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Ambient temperature (operation) -20 °C ... 65 °C
- Reference voltage source < 3.6 V
- Current output signal 0 mA ... 20 mA
- Nominal supply voltage 24 V DC
- Connection method Screw connection
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Conductor cross section AWG 26 ... 12
- Noise emission EN 61000-6-4
- Connection in acc. with standard CUL
- Width 6.2 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Load/output load voltage output > 10 kΩ
- Stripping length 12 mm
- Maximum temperature coefficient < 0.02 %/K
- Standards/regulations EN 61000-4-6
- Electromagnetic compatibility Conformance with EMC directive
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Degree of protection IP20
- Max. voltage output signal 12.5 V
- Supply voltage range 19.2 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
- Power consumption < 500 mW
- Temperature coefficient, typical < 0.02 %/K
- Designation Shipbuilding approval
- Temperature B
- Height 93.1 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Max. current output signal 23 mA
- Load/output load current output < 500 Ω (20 mA)
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Housing material PBT
- Typical deviation from the measuring range final value 5 %
- Identification UL 508 Recognized
- Certificate DNV GL TAA00000N1
- EMC A
- ECLASS 10.0.1 27210120
- ECLASS 4.0 27210100
- ETIM 7.0 EC002653
- UNSPSC 6.01 30211506
- UNSPSC 18.0 39121008
- UNSPSC 21.0 39121008
- Depth 101.2 mm
- Maximum altitude ≤ 2000 m
- Potentiometer 100 Ω ... 100 kΩ
- Voltage output signal 0 V ... 5 V
- Typical current consumption < 25 mA (at 24 V DC)
- Screw thread M3
- Maximum transmission error < 0.2 %
- Color green
- Electrical isolation Basic insulation according to EN 61010
- Humidity B
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 5.0 27210100
- ECLASS 9.0 27210120
- UNSPSC 11 39121008
- UNSPSC 12.01 39121008
- Vibration B
- ECLASS 11.0 27210120
- REACh SVHC Lead 7439-92-1
- ECLASS 5.1 27210100
- ECLASS 6.0 27210100
- ETIM 6.0 EC002653
- UNSPSC 19.0 39121008
- Enclosure A
- ECLASS 4.1 27210100
- ECLASS 7.0 27210120
- ETIM 4.0 EC002653
- UNSPSC 7.0901 39121008
- UNSPSC 13.2 39121008
- UNSPSC 20.0 39121008
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?