2838228 Phoenix Contact Electrical Measuring & Monitoring Instruments

2838228 on Power Resource International
Phoenix Contact

Part#:2838228

Manufacturer:Phoenix Contact

Category:Electrical Measuring & Monitoring Instruments

Product Lifecycle:Active

Get a quick Quote!

PT protective connector with protective circuit for two 2-wire floating signal circuits. 24 V DC nominal voltage. HART-compatible.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2838228 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Horizontal pitch
    1 Div.
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Housing material
    PA 6.6
  • Overvoltage category
    II
  • Nominal voltage UN
    24 V DC
  • Operating effective current IC at UC
    ≤ 5 µA
  • Nominal discharge current In (8/20) µs (line-earth)
    10 kA
  • Nominal pulse current Ian (10/1000) µs (line-line)
    25 A
  • Output voltage limitation at 1 kV/µs (line-earth) spike
    ≤ 450 V (with PT 2X2-BE)
  • Voltage protection level Up (line-line)
    ≤ 70 V (C1 - 1 kV/500 A)
  • Response time tA (line-earth)
    ≤ 100 ns
  • Cut-off frequency fg (3 dB), sym. in 50 Ω system
    typ. 4.5 MHz
  • Max. required back-up fuse
    500 mA (T)
  • Impulse durability (line-earth)
    C1 - 1 kV / 500 A
  • Connection method
    Screw connection (in connection with the base element)
  • Standards/specifications
    IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
  • ECLASS 11.0
    27130807
  • ECLASS 4.0
    27130800
  • ETIM 2.0
    EC000943
  • UNSPSC 6.01
    30212010
  • UNSPSC 18.0
    39121620
  • UNSPSC 12.01
    39121610
  • UNSPSC 21.0
    39121620
  • Depth
    51.7 mm
  • Complete module depth
    65.5 mm
  • Ambient temperature (operation)
    -40 °C ... 85 °C
  • Flammability rating according to UL 94
    V-0
  • Degree of pollution
    3
  • Type
    Male
  • IEC test classification
    C1
  • Pulse discharge current Iimp (10/350) µs
    2.5 kA
  • Max. discharge current Imax (8/20) µs maximum (line-line)
    10 kA
  • Output voltage limitation at 1 kV/µs (line-earth) static
    ≤ 25 V (with PT 2X2-BE)
  • Residual voltage at In (line-signalground)
    ≤ 450 V
  • Voltage protection level Up (line-earth)
    ≤ 450 V (C1 - 1 kV / 500 A with PT 2X2-BE)
  • Capacity (line-earth)
    typ. 8 pF (with PT 2X2-BE)
  • Cut-off frequency fg (3 dB), sym. in 150 Ω system
    typ. 1.5 MHz
  • Capacity (line-line)
    typ. 1.4 nF
  • Tightening torque
    0.5 Nm
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • ECLASS 10.0.1
    27130807
  • ECLASS 4.1
    27130800
  • ECLASS 6.0
    27130800
  • ETIM 6.0
    EC000943
  • UNSPSC 11
    39121610
  • Width
    17.5 mm
  • Complete module width
    17.7 mm
  • Degree of protection
    IP20
  • Direction of action
    Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
  • Note
    Technical data is valid in association with the following specified base elements:
  • Rated current
    450 mA (45 °C)
  • Nominal discharge current In (8/20) µs (line-line)
    10 kA
  • Max. discharge current Imax (8/20) µs maximum (line-earth)
    10 kA
  • Output voltage limitation at 1 kV/µs (line-line) spike
    ≤ 45 V
  • Residual voltage with Ian (10/1000) µs (line-line)
    ≤ 50 V
  • Voltage protection level Up static (line-earth)
    ≤ 50 V (C2 - 10 kV / 5 kA with PT 2X2-BE)
  • Response time tA (line-line)
    ≤ 1 ns
  • Cut-off frequency fg (3 dB), sym. in 600 Ω system
    typ. 600 kHz
  • Resistance per path
    2.2 Ω ±10 %
  • Screw thread
    M3
  • Conductor cross section AWG
    24 ... 12
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.0
    27130800
  • ECLASS 7.0
    27130807
  • ETIM 4.0
    EC000943
  • UNSPSC 7.0901
    39121610
  • UNSPSC 19.0
    39121620
  • Height
    44.8 mm
  • Complete module height
    90 mm
  • Altitude
    ≤ 2000 m (amsl (above mean sea level))
  • Color
    jet black RAL 9005
  • Mounting type
    on base element
  • Arrester can be tested with CHECKMASTER from software version:
    From SW rev. 1.00
  • Maximum continuous voltage UC
    28 V DC
  • Residual current IPE
    ≤ 1 µA (with PT 2X2+F-BE)
  • Total discharge current Itotal (8/20) µs
    20 kA
  • Output voltage limitation at 1 kV/µs (line-line) static
    ≤ 40 V
  • Residual voltage at In (line-line)
    ≤ 40 V
  • Voltage protection level Up static (line-line)
    ≤ 40 V (C2 - 10 kV / 5 kA)
  • Input attenuation aE, sym.
    typ. 0.5 dB (≤ 1 MHz / 50 Ω)
  • Surge protection fault message
    none
  • Impulse durability (line-line)
    C1 - 1 kV / 500 A
  • Stripping length
    8 mm
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27130800
  • ECLASS 9.0
    27130807
  • ETIM 3.0
    EC000943
  • ETIM 7.0
    EC000943
  • UNSPSC 13.2
    39121620
  • UNSPSC 20.0
    39121620

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?