2811763 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2811763
Manufacturer:Phoenix Contact
Category:Electrical Measuring & Monitoring Instruments
Product Lifecycle:Active
Get a quick Quote!
Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, S
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2811763 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 17.5 mm
- Ambient temperature (operation) -20 °C ... 65 °C
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Load/output load voltage output ≥ 10 kΩ
- Behavior in the event of a sensor error according to NE 43 or freely configurable
- Depth 114.5 mm
- Max. voltage output signal ± 11 V
- Supply voltage range 24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
- Connection method Screw connection
- Maximum temperature coefficient 0.01 %/K
- Degree of pollution 2
- Housing material PA 6.6-FR
- ECLASS 5.1 27210100
- ECLASS 9.0 27210120
- UNSPSC 20.0 39121008
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Permissible humidity (operation) typ. 5 % ... 95 % (non-condensing)
- Vibration (operation) 5g, accordance to IEC 60068-2-6
- Maximum switching voltage 30 V AC (30 V DC)
- Typical current consumption < 50 mA (24 V DC)
- Maximum altitude ≤ 2000 m
- Sensor types (RTD) that can be used Pt, Ni, Cu sensors: 2, 3, 4-wire
- ECLASS 4.1 27210100
- ECLASS 7.0 27210120
- UNSPSC 11 39121008
- UNSPSC 6.01 30211506
- UNSPSC 19.0 39121008
- Contact type 1 changeover contact
- Load/output load current output ≤ 600 Ω (at 20 mA)
- Mechanical service life 1x 105 cycles
- ECLASS 11.0 27210120
- ECLASS 4.0 27210100
- ECLASS 6.0 27210100
- ETIM 4.0 EC002653
- UNSPSC 7.0901 39121008
- UNSPSC 21.0 39121008
- Max. output power Po 11 mW
- Contact material AgSnO2, hard gold-plated
- Screw thread M3
- Torque 0.5 Nm ... 0.6 Nm
- Overvoltage category II
- Color gray
- ECLASS 10.0.1 27210120
- ECLASS 5.0 27210100
- ETIM 6.0 EC002653
- UNSPSC 12.01 39121008
- UNSPSC 18.0 39121008
- Electromagnetic compatibility Conformance with EMC directive
- Electrical isolation 4-way, between input/output/power supply/switching output
- Max. output current Io 7.4 mA
- Group IIC
- Typical deviation from the measuring range final value 2 %
- DNV GL-Humidity B
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- ETIM 7.0 EC002653
- UNSPSC 13.2 39121008
- Max. external capacitance Co 15 µF
- Noise emission EN 61000-6-4
- Current output signal 4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
- Maximum inrush current 0.5 A (30 V AC)
- ATEX II (1) G [Ex ia Ga] IIC
- DNV GL-Temperature B
- Humidity B
- Degree of protection IP20 (not assessed by UL)
- Potentiometer resistance range 0 Ω ... 50 kΩ
- Power consumption < 1.5 W
- Stripping length 7 mm
- Interference emission EN 61000-6-4
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Max. output voltage Uo 6 V
- Max. external inductivity Lo 1 mH
- DNV GL-Vibration A
- Temperature B
- REACh SVHC Lead 7439-92-1
- Sensor types that can be used (TC) B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
- Temperature measuring range -250 °C ... 2500 °C (Range depending on the sensor type)
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Step response (0–99%) typ. 1000 ms (With SIL)
- Designation EAC Ex
- Safety-related maximum voltage Um 253 V AC/DC
- IECEx [Ex ia Ga] IIC
- Certificate RU C-DE.AB72.B.00093/19
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- Max. current output signal 22 mA
- Output name Switching output
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Max. internal inductance Li negligible
- Max. internal capacitance Ci 44 nF
- Standards/regulations EN 61000-4-6
- UL, USA/Canada UL 508 Listed
- DNV GL-EMC A
- EMC A
- Vibration A
- Height 112.5 mm
- Shock 15g, according to IEC 60068-2-27
- Input signal range -1000 mV ... 1000 mV
- Conductor cross section AWG 24 ... 14
- Status display Green LED (supply voltage, PWR)
- Rated insulation voltage 300 Vrms
- Conformance CE-compliant
- Identification [Ex ia Ga] IIC
- China RoHS Environmentally Friendly Use Period = 50 years
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?