Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, S

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2811763 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Width
    17.5 mm
  • Ambient temperature (operation)
    -20 °C ... 65 °C
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Load/output load voltage output
    ≥ 10 kΩ
  • Behavior in the event of a sensor error
    according to NE 43 or freely configurable
  • Depth
    114.5 mm
  • Max. voltage output signal
    ± 11 V
  • Supply voltage range
    24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
  • Connection method
    Screw connection
  • Maximum temperature coefficient
    0.01 %/K
  • Degree of pollution
    2
  • Housing material
    PA 6.6-FR
  • ECLASS 5.1
    27210100
  • ECLASS 9.0
    27210120
  • UNSPSC 20.0
    39121008
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Permissible humidity (operation)
    typ. 5 % ... 95 % (non-condensing)
  • Vibration (operation)
    5g, accordance to IEC 60068-2-6
  • Maximum switching voltage
    30 V AC (30 V DC)
  • Typical current consumption
    < 50 mA (24 V DC)
  • Maximum altitude
    ≤ 2000 m
  • Sensor types (RTD) that can be used
    Pt, Ni, Cu sensors: 2, 3, 4-wire
  • ECLASS 4.1
    27210100
  • ECLASS 7.0
    27210120
  • UNSPSC 11
    39121008
  • UNSPSC 6.01
    30211506
  • UNSPSC 19.0
    39121008
  • Contact type
    1 changeover contact
  • Load/output load current output
    ≤ 600 Ω (at 20 mA)
  • Mechanical service life
    1x 105 cycles
  • ECLASS 11.0
    27210120
  • ECLASS 4.0
    27210100
  • ECLASS 6.0
    27210100
  • ETIM 4.0
    EC002653
  • UNSPSC 7.0901
    39121008
  • UNSPSC 21.0
    39121008
  • Max. output power Po
    11 mW
  • Contact material
    AgSnO2, hard gold-plated
  • Screw thread
    M3
  • Torque
    0.5 Nm ... 0.6 Nm
  • Overvoltage category
    II
  • Color
    gray
  • ECLASS 10.0.1
    27210120
  • ECLASS 5.0
    27210100
  • ETIM 6.0
    EC002653
  • UNSPSC 12.01
    39121008
  • UNSPSC 18.0
    39121008
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Electrical isolation
    4-way, between input/output/power supply/switching output
  • Max. output current Io
    7.4 mA
  • Group
    IIC
  • Typical deviation from the measuring range final value
    2 %
  • DNV GL-Humidity
    B
  • DNV GL-Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ETIM 7.0
    EC002653
  • UNSPSC 13.2
    39121008
  • Max. external capacitance Co
    15 µF
  • Noise emission
    EN 61000-6-4
  • Current output signal
    4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
  • Maximum inrush current
    0.5 A (30 V AC)
  • ATEX
     II (1) G [Ex ia Ga] IIC
  • DNV GL-Temperature
    B
  • Humidity
    B
  • Degree of protection
    IP20 (not assessed by UL)
  • Potentiometer resistance range
    0 Ω ... 50 kΩ
  • Power consumption
    < 1.5 W
  • Stripping length
    7 mm
  • Interference emission
    EN 61000-6-4
  • Insulation
    Safe isolation in accordance with IEC/EN 61010-1
  • Max. output voltage Uo
    6 V
  • Max. external inductivity Lo
    1 mH
  • DNV GL-Vibration
    A
  • Temperature
    B
  • REACh SVHC
    Lead 7439-92-1
  • Sensor types that can be used (TC)
    B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
  • Temperature measuring range
    -250 °C ... 2500 °C (Range depending on the sensor type)
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Step response (0–99%)
    typ. 1000 ms (With SIL)
  • Designation
    EAC Ex
  • Safety-related maximum voltage Um
    253 V AC/DC
  • IECEx
    [Ex ia Ga] IIC
  • Certificate
    RU C-DE.AB72.B.00093/19
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • Max. current output signal
    22 mA
  • Output name
    Switching output
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Test voltage
    2.5 kV AC (50 Hz, 1 min.)
  • Max. internal inductance Li
    negligible
  • Max. internal capacitance Ci
    44 nF
  • Standards/regulations
    EN 61000-4-6
  • UL, USA/Canada
    UL 508 Listed
  • DNV GL-EMC
    A
  • EMC
    A
  • Vibration
    A
  • Height
    112.5 mm
  • Shock
    15g, according to IEC 60068-2-27
  • Input signal range
    -1000 mV ... 1000 mV
  • Conductor cross section AWG
    24 ... 14
  • Status display
    Green LED (supply voltage, PWR)
  • Rated insulation voltage
    300 Vrms
  • Conformance
    CE-compliant
  • Identification
     [Ex ia Ga] IIC
  • China RoHS
    Environmentally Friendly Use Period = 50 years

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?