Inline power-level terminal blocks, electronic direct starter, up to 1.5Ā kWĀ / 400Ā VĀ AC
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2727352 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 63 mm
- Permissible humidity (operation) 10 % ... 85 % (non-condensing)
- Degree of protection IP20
- Designation Segment circuit supply (US)
- Number 1
- Frequency range 50 Hz ... 60 Hz
- Overspeed tripping ā„ 20 A (after 0.3 seconds)
- Current consumption max. 50 mA
- Net weight 450 g
- Operating mode Process data mode with one byte
- Mounting position Panel mounting on horizontal DIN rail
- REACh SVHC Lead 7439-92-1
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (operation) -25 Ā°C ... 55 Ā°C
- Permissible humidity (storage/transport) 10 % ... 85 % (non-condensing)
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000Ā m above sea level)
- Number of positions 4
- Nominal current range 0.2 A ... 3.6 A
- Connection technology COMBICON
- Note on weight specifications without plug
- Assembly instructions To safeguard sufficient ventilation, ensure that there is an installation clearance of a minimum of 50Ā cm both above and below.
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) ENĀ 61000-4-4/IECĀ 61000-4-4 Criterion B; Supply lines: 2 kV; Signal/data lines: 2 kV
- Depth 109 mm
- Ambient temperature (storage/transport) -25 Ā°C ... 85 Ā°C
- Connection method COMBICON
- Designation connection point Terminal strip X10
- Type of contact Solid-state contact
- Mounting type DIN rail
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields ENĀ 61000-4-3/IECĀ 61000-4-3 Criterion A, field strength: 3 V/m
- Interference emission Noise emission test as per EN 61000-6-4 Radio interference properties EN 55011 Class A
- ECLASS 4.1 27250300
- ECLASS 6.0 27242600
- UNSPSC 6.01 43172015
- UNSPSC 18.0 32151602
- Height 224 mm
- Air pressure (operation) 70 kPa ... 106 kPa (up to 2000Ā m above sea level)
- Note Notes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector
- Transmission speed 500 kbps
- Permissible conductor cross section 1 mmĀ² ... 2.5 mmĀ²
- Output name Motor output
- Parameterization range 0.2 A ... 3.6 A (steps of 50/100/200 mA, via fieldbus)
- Supply voltage 24 VĀ DC (via voltage jumper)
- Power consumption max. 1.2 W (entire device)
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) ENĀ 61000-4-2/IECĀ 61000-4-2 6 kV contact discharge, criterion B, 8 kV air discharge, criterion B
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 5.1 27242600
- ECLASS 11.0 27242609
- Transmission physics Copper
- Operating voltage 200 VĀ AC ... 440 VĀ AC
- Max. current carrying capacity 20 A
- Switching rate Max. 30 per minute (observe derating)
- Supply voltage range 19.2 VĀ DC ... 28.8 VĀ DC (including all tolerances, including ripple)
- Diagnostics messages Overcurrent Error message in the diagnostic code (bus) and display via the LED ERR on the module
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) ENĀ 61000-4-5/IECĀ 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symm./asymm.), criterion B, supply lines AC: 2 kV/4 kV (symm./asymm.)
- ECLASS 9.0 27242609
- ETIM 6.0 EC001605
- UNSPSC 7.0901 43201404
- UNSPSC 13.2 32151602
- Protection class I (ŠŠŠĀ 61140, ENĀ 61140, VDEĀ 0140-1)
- ECLASS 5.0 27250300
- ETIM 4.0 EC001601
- ETIM 7.0 EC001605
- UNSPSC 19.0 32151602
- UNSPSC 20.0 32151602
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference ENĀ 61000-4-6/IECĀ 61000-4-6 Criterion A, Test voltage 10 V
- Mechanical tests Vibration resistance in acc. with ENĀ 60068-2-6/IECĀ 60068-2-6 2g, evaluation criterion 1
- ECLASS 10.0.1 27242609
- ECLASS 4.0 27250300
- ECLASS 7.0 27242609
- ETIM 3.0 EC001601
- ETIM 2.0 EC001433
- UNSPSC 11 43172015
- UNSPSC 12.01 43201404
- UNSPSC 21.0 32151602
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?