FO converter with integrated optical diagnostics, alarm contact, for RS-485 2-wire bus systems (SUCONET K, Modbus ...) up to 500 kbps, NRZ coding, T-coupler with two FO interfaces (FSMA), 660 nm, for polymer/PCF fiber cable
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Data & Networking Devices that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2708300 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- ETIM 4.0 EC001423
- Height 99 mm
- UNSPSC 12.01 39121008
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Max. current consumption 130 mA
- Typical current consumption 100 mA (24 V DC)
- Transmission medium Polymer fiber
- Width 35 mm
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section AWG max. 14
- Bit delay ≤ 1 bit
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Permissible humidity (operation) 30 % ... 95 % (non-condensing)
- Noise immunity EN 61000-6-2:2005
- Noise emission EN 55011
- Supply voltage range 18 V DC ... 30 V DC (via pluggable COMBICON screw terminal block)
- Operating mode Semi-duplex
- Conductor cross section solid min. 0.2 mm²
- Serial transmission speed 4.8/ 9.6/ 19.2/ 38.4/ 57.6/ 75/ 93.75/ 115.2/ 136/ 187.5/ 375/ 500 kbps
- Minimum receiver sensitivity -30.2 dBm
- Maximum switching voltage 60 V DC
- Identification DNV GL
- Ambient temperature (operation) -20 °C ... 60 °C
- Bit distortion, output < 6.25 %
- Net weight 201.08 g
- Color green
- Interface 1 RS-485 interface, 2-wire
- Transmission length min. 1 m ()
- Termination resistor 390 Ω
- No. of channels 2
- Wavelength 660 nm
- Limiting continuous current 0.46 A
- Certificate PTB 06 ATEX 2042 U
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- UNSPSC 7.0901 39121008
- Degree of protection IP20
- Bit distortion, input ± 35 % (permitted)
- MTBF 220 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
- Conductor cross section flexible max. 2.5 mm²
- Conductor cross section solid max. 2.5 mm²
- Output description Alarm output
- Additional text Please follow the special installation instructions in the documentation!
- Vibration A
- Connection in acc. with standard CUL
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 10.0.1 19170132
- UNSPSC 11 39121008
- UNSPSC 21.0 43223323
- Electrical isolation VCC // RS-485
- Data direction switching Automatic control
- File format/coding UART (11/10 bit switchable; NRZ), slip-tolerant
- Conductor cross section AWG min. 24
- Overrange receiver -3 dBm (980/1000 µm)
- Transmission protocol Protocol-transparent to the RS-485 interface
- Designation Air clearances and creepage distances
- Temperature B
- Free from substances that could impair the application of coating according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard
- Standards/regulations DIN EN 60664-1
- UNSPSC 6.01 30211506
- UNSPSC 19.0 43223323
- Type of test Shock in acc. with EN 60068-2-27/IEC 60068-2-27
- Signal ± 1 kV
- UNSPSC 20.0 43223323
- Humidity A
- Mounting type DIN rail mounting
- Nominal supply voltage 24 V DC (in acc. with UL)
- Output name Relay output
- REACh SVHC Lead 7439-92-1
- ECLASS 6.0 19179200
- Test voltage data interface/power supply 1.5 kVrms (50 Hz, 1 min.)
- Transmit capacity, minimum -5.3 dBm (980/1000 µm)
- Transmission length incl. 3 dB system reserve 100 m (With F-P 980/1000 230 dB/km with quick mounting connector)
- Housing material PA 6.6-FR
- ECLASS 5.0 27230200
- ETIM 6.0 EC001467
- ETIM 3.0 EC001423
- Depth 105 mm
- Altitude ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
- Connection method F-SMA
- Comments Criterion B
- ECLASS 4.1 27230200
- ECLASS 9.0 19170114
- ETIM 7.0 EC001467
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- UNSPSC 13.2 43222604
- ECLASS 4.0 27230200
- Number of outputs 1
- Test result 15g, 11 ms period, half-sine shock pulse
- ECLASS 7.0 19179290
- ETIM 2.0 EC001423
- EMC B
- UNSPSC 18.0 43223323
- Contact discharge ± 6 kV
- ECLASS 5.1 27230200
- ECLASS 11.0 19170411
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?