About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2702522 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 17.5 mm
- Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
- Maximum altitude ≤ 2000 m (Above sea level)
- Power consumption at UD typ. 0.9 W (at UD; Off state)
- Protective circuit Surge protection 36Â V suppressor diode (A1-A2)33Â V suppressor diode (24V-GND)
- Current consumption typ. 20 mA (Input TP1)
- Number of outputs 1 (without delay, floating)
- Relay type Electromechanical relay
- Status display 1 x yellow LED, 1 x green LED, 1 x red LED
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Standards/regulations DINÂ ENÂ 50178
- Rated surge voltage/insulation Basic insulation 4Â kV between all current paths and housing
- Conformance CE-compliant
- ECLASS 5.1 27371901
- Depth 114.5 mm
- Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
- Rated control supply current IS typ. 75 mA
- Filter time 2 ms (at A1-A2 in the event of voltage dips at Us)
- Description of the input Test point for proof test
- Contact type 1 signaling current path
- Switching voltage min. 16 V AC/DC
- Switching frequency max. 0.5 Hz
- Typical release time at US typ. 30 ms (when controlled via A1-A2)
- Mounting position vertical or horizontal
- Housing color yellow
- pluggable Yes
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Degree of pollution 2
- Environmental simulation test ISA-S71.04 (G3)
- ECLASS 6.0 27371800
- Ambient temperature (operation) -25 °C ... 60 °C (observe derating)
- Air pressure (operation) 79 kPa ... 106 kPa
- Inrush current max. 800 mA (Δt  100 ms)
- Input current at UD 35 mA (at UD = 24Â V)
- Output name Signaling current path
- Contact material AgNi, gold-flashed, Ag alloy
- Switching capacity min. 1 W
- Short-circuit protection no
- Typical pickup time at US typ. 100 ms (when controlled via A1-A2)
- Degree of protection IP20
- Min. degree of protection of inst. location IP54
- Connection method Screw connection
- Screw thread M3
- Rated insulation voltage 250 VÂ AC
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 7.0 27371819
- ETIM 6.0 EC001449
- Height 112.2 mm
- Rated control circuit supply voltage US 24 VÂ DC -15 % / +10 %
- Power consumption at US typ. 2 W (at US/UD; On state)
- Type of protection Surge protection
- Output description non-safety-related N/C contact
- Sq. Total current 9 A2 (observe derating)
- Mechanical service life approx. 5x 107 cycles
- Recovery time 1 s (when controlled via A1-A2)
- Assembly instructions See derating curve
- Housing material Frianyl A 63 R V0
- Stripping length 7 mm
- Designation Air clearances and creepage distances between the power circuits
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- REACh SVHC Lead 7439-92-1
- ECLASS 9.0 27371819
- ETIM 7.0 EC001449
- Utilization restriction Use in potentially explosive areas is not permitted in China.
- Ambient temperature (storage/transport) -40 °C ... 65 °C
- Air pressure (storage/transport) 79 kPa ... 106 kPa
- Diagnostic supply voltage UD 24 VÂ DC -20Â %Â /Â +25Â %
- Inrush current at UD 1.5 A (Δt < 10 µs)
- Number of inputs 3
- Protective circuit/component 36Â V suppressor diode
- Limiting continuous current 3 A (Observe derating, load type, and on-load voltage)
- Diagnostic threshold 7 Ω ... 20 kΩ (configurable)
- Net weight 147.48 g
- Nominal operating mode 100% operating factor
- Mounting type DIN rail mounting
- Conductor cross-section AWG 24 ... 12
- Safety Integrity Level (SIL) 3 (Reference IECÂ 61508)
- Overvoltage category III
- Shock 15g, 11Â ms
- ECLASS 10.0.1 27371819
- ECLASS 11.0 27371819
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?