Safety relay for emergency switching off and safety doors as well as for elevator applications up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, automatic or manual start, cross-circuit detection, 3 enabling current paths, US = 24 V DC, pluggable Pus
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2702412 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Ambient temperature (operation) -40 °C ... 60 °C (observe derating)
- Rated control supply current IS typ. 70 mA
- Inrush current min. 10 mA
- Input voltage range "0" signal 0 V DC ... 5 V DC (for safe Off; at S12 and S22)
- Input voltage range "1" signal 19.2 V DC ... 30 V DC
- Contact material AgSnO2
- Maximum interrupting rating (inductive load) 48 W (24 V DC, τ = 40 ms)
- Switching capacity according to IEC 60947-5-1 5 A (24 V (DC13))
- Typical pickup time at US < 100 ms (when controlled via A1)
- Recovery time < 500 ms
- Nominal operating mode 100% operating factor
- Connection method Push-in connection
- Conductor cross-section AWG 24 ... 16
- Stripping length 8 mm
- Degree of pollution 2
- REACh SVHC Lead 7439-92-1
- ECLASS 5.0 27371900
- ETIM 3.0 EC001449
- UNSPSC 13.2 39121501
- UNSPSC 21.0 39122205
- Depth 114.5 mm
- Maximum altitude ≤ 2000 m (Above sea level)
- Input name Start circuit
- Output description non-safety-related
- Switching voltage min. 5 V AC/DC
- Switching frequency 0.5 Hz
- Short-circuit protection Yes
- Net weight 202.5 g
- Housing color yellow
- Operating voltage display 1 x green LED
- Status display 3 x green LED
- Category 4
- Rated insulation voltage 250 V AC
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Designation Air clearances and creepage distances between the power circuits
- Protective circuit Surge protection Suppressor diode
- Input current range "0" signal 0 mA ... 2 mA (for safe Off; at S12 and S22)
- Filter time max. 3 ms (at S12, S22; test pulse width; blanking pulses/dark test)
- Protective circuit/component Suppressor diode
- Contact type 1 signaling current path
- Sq. Total current 1 A2
- Output fuse 1 A gL/gG
- Current max. 100 mA
- Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Restart time < 1 s (Boot time)
- Assembly instructions See derating curve
- pluggable Yes
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Safety Integrity Level (SIL) 3
- Overvoltage category II
- Conformance CE-compliant
- ECLASS 11.0 27371819
- ECLASS 5.1 27371900
- ECLASS 7.0 27371819
- UNSPSC 18.0 39122205
- UNSPSC 20.0 39122205
- Height 117.4 mm
- Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
- Power consumption at US typ. 1.68 W
- Description of the input non-safety-related
- Max. permissible overall conductor resistance 150 Ω
- Number of inputs 1
- Output name Signaling current path
- Limiting continuous current 1 A
- Interrupting rating (ohmic load) max. 1500 VA (250 V AC, τ = 0 ms)
- Mechanical service life 10x 106 cycles
- Maximum inrush current 1 A (Δt = 5 ms at Us)
- Typical response time at US < 100 ms (automatic start)
- Mounting type DIN rail mounting
- Degree of protection IP20
- Conductor cross-section flexible with ferrule and plastic sleeve 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
- Performance level (PL) e (5 A DC13; 5 A AC15; 8760 switching cycles/year)
- Safety Integrity Level Claim Limit (SIL CL) 3
- Rated surge voltage/insulation Basic insulation 4 kV between all current paths
- Shock 15g for Δt = 11 ms (continuous shock: 10g for Δt = 16 ms)
- ECLASS 6.0 27371800
- ECLASS 9.0 27371819
- ETIM 7.0 EC001449
- UNSPSC 19.0 39122205
- Width 22.5 mm
- Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
- Rated control circuit supply voltage US 24 V DC -20 % / +25 %
- Current consumption < 0.5 mA
- Number of outputs 1 (digital)
- Switching capacity min. 50 mW
- Voltage 23 V DC (Us - 1 V)
- Typical release time at US < 20 ms (when controlled via A1 or S12)
- Mounting position vertical or horizontal
- Min. degree of protection of inst. location IP54
- Conductor cross section solid 0.2 mm² ... 1.5 mm²
- Conductor cross-section flexible with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
- Stop category 0
- Standards/regulations DIN EN 60664-1:2008
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- ECLASS 10.0.1 27371819
- ECLASS 4.1 40020600
- ECLASS 4.0 40020600
- ETIM 4.0 EC001449
- ETIM 6.0 EC001449
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.