2702291 Phoenix Contact Programmable Logic Controllers
Part#:2702291
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline F, Digital I/O module, Digital inputs: 16, 24 V DC, connection method: 1-conductor, Digital outputs: 8, 24 V DC, 2 A, connection method: 2-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base mo
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2702291 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 35 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- Conductor cross section flexible max. 1.5 mm²
- Mounting type DIN rail
- Current consumption max. 16 A (Provide external protection; if the total current of 8 A is exceeded, connect the supply at the power connector parallel via both terminal points.)
- Protection max. 16 A (polarity reversal protection up to 5 A)
- Nominal input voltage UIN 24 V DC
- Number of outputs 8
- Output voltage when switched off max. 1 V
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- UNSPSC 13.2 32151602
- Net weight 111 g
- UNSPSC 21.0 32151602
- Caption Dimensions
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible min. 0.2 mm²
- Number of interfaces 2
- Protective circuit Short-circuit protection, overload protection of the outputs electronic
- Input name Digital inputs
- Input filter time 3000 µs (Default)
- ECLASS 10.0.1 27242604
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of protection IP20
- Conductor cross section AWG min. 24
- Note on weight specifications with connectors and bus base module
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Overvoltage category II (IEC 60664-1, EN 60664-1)
- ECLASS 5.1 27242600
- ETIM 6.0 EC001599
- Degree of pollution 2 (IEC 60664-1, EN 60664-1)
- Supply voltage 24 V DC
- Description of the input EN 61131-2 types 1 and 3
- Nominal input current at UIN 2.4 mA
- Output voltage 24 V DC
- Switching frequency max. 3000 per second (with at least 50 mA load current)
- Nominal load, lamp max. 48 W (at nominal voltage)
- UNSPSC 18.0 32151602
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Nominal load, ohmic max. 48 W (12 Ω, at nominal load)
- Reverse voltage resistance to short pulses limited protection up to 0.5 A for 1 s
- Depth 54 mm
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Conductor cross section solid max. 1.5 mm²
- Stripping length 8 mm
- Transmission speed 100 Mbps
- Power consumption max. 480 W (of which 6.4 W internal losses)
- Number of inputs 16
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 7.0 27242604
- UNSPSC 20.0 32151602
- ECLASS 11.0 27242604
- ETIM 7.0 EC001599
- Height 129.9 mm
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Designation Supply for digital input and output modules (UIO)
- Connection method Push-in connection
- Color traffic grey A RAL 7042
- Conductor cross section AWG max. 16
- Mounting position any (no temperature derating)
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Connection technology 2-conductor
- Output name Digital outputs
- Nominal output voltage 24 V DC
- Load min. 10 kΩ
- Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
- Behavior with overload Shutdown with automatic restart
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 9.0 27242604
- UNSPSC 19.0 32151602
- Input voltage range "0" signal -3 V DC ... 5 V DC
- Nominal load, inductive max. 48 VA (1.2 H, 12 Ω, at nominal load)
- Output current when switched off max. 300 µA
- Behavior with inductive overload Output can be destroyed
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- REACh SVHC Lead 7439-92-1
- ECLASS 6.0 27242600
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?