2702289 Phoenix Contact Programmable Logic Controllers
Part#:2702289
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Inline, Block IO, PROFINET, RJ45 jack, Digital inputs: 32 (16 fixed and 16 freely selectable), 24 V DC, connection method: 3-conductor, Digital outputs: 16, 24 V DC, 500 mA, connection method: 2-conductor, PROFINET, -IRT, -MRP, -Fast Startup, degree of pr
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2702289 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Depth 57 mm
- Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
- Net weight 563.9 g
- Note on weight specifications with connectors
- Transmission speed 100 Mbps (acc. to PROFINET standard)
- Transmission physics Ethernet in RJ45 twisted pair
- Typical response time approx. 500 µs
- Nominal input current at UIN approx. 2.4 mA
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Output name Digital outputs
- Nominal load, inductive 12 VA (1.2 H, 48 Ω)
- Behavior with overload Auto restart
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 4 kV contact discharge, 8 kV air discharge
- ETIM 3.0 EC001599
- Note on dimensions Specfications with connectors
- Ambient temperature (operation) -25 °C ... 60 °C
- Air pressure (storage/transport) 66 kPa ... 108 kPa (up to 3500 m above sea level)
- Note on the connection method Autonegotiation and autocrossing, X2: internally crossed to enable “Fast Startup” with patch cable
- Designation connection point X1, X2
- Connection technology 2-conductor
- Typical input current per channel typ. 5 mA
- ECLASS 11.0 27242604
- ECLASS 4.0 27250302
- UNSPSC 6.01 43172015
- UNSPSC 13.2 32151602
- Width 156 mm
- Permissible humidity (operation) 10 % ... 95 % (non-condensing)
- Diagnostics messages Short-circuit or overload of the digital outputs Message in the diagnostics register
- Input name Digital inputs
- Input voltage 24 V DC
- Number of outputs 16
- Nominal load, lamp 12 W
- Behavior with inductive overload Output can be destroyed
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27250302
- ECLASS 6.0 27242600
- Protective circuit Short-circuit and overload protection Free-wheeling diode, integrated per channel
- Height 141 mm
- Air pressure (operation) 80 kPa ... 108 kPa (up to 2000 m above sea level)
- Mounting type DIN rail
- Number 2
- Connection method Inline connector
- Number of inputs 32 (16 fixed and 16 freely selectable)
- Nominal input voltage UIN 24 V DC
- Nominal load, ohmic 12 W (48 Ω)
- Nominal output voltage 24 V DC
- Reverse voltage resistance to short pulses limited protection up to 0.5 A for 1 s
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Overvoltage category II
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Degree of protection IP20
- Designation PROFINET
- Description of the input EN 61131-2 types 1 and 3
- Input voltage range "0" signal -3 V DC ... 5 V DC
- Output voltage 24 V DC -1 V (At nominal current)
- Output current when switched off max. 300 µA (When not loaded, a voltage can be measured even at an output that is not set.)
- Test section I/Os / logic 500 V AC 50 Hz 1 min.
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±1 kV (symmetrical/asymmetrical), signal lines: ±1 kV/±1 kV (symmetrical/asymmetrical)
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 5.0 27250302
- ETIM 2.0 EC001430
- UNSPSC 19.0 32151602
- UNSPSC 18.0 32151602
- Interference emission Noise emission test as per EN 61000-6-4 EN 55011 Class A
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 9.0 27242604
- ETIM 7.0 EC001599
- UNSPSC 7.0901 43201404
- UNSPSC 21.0 32151602
- UNSPSC 11 43172015
- UNSPSC 12.01 43201404
- ECLASS 10.0.1 27242604
- ECLASS 7.0 27242604
- ECLASS 5.1 27242604
- ETIM 4.0 EC001599
- UNSPSC 20.0 32151602
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV
- ETIM 6.0 EC001599
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?