Safety relay for emergency stop, safety doors, light grid up to SILCL 1, Cat. 1, PL e, 1- or 2-channel operation, cross-circuit detection, can be retriggered, fall back/on delay 0.2 s to 60 s, 2 enabling current paths, US = 24 V DC, pluggable Push-in term

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2702095 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Number of outputs
    1
  • Contact material
    AgSnO2
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Width
    12.5 mm
  • Max. permissible relative humidity (operation)
    75 % (on average, 85% infrequently, non-condensing)
  • Rated control supply current IS
    typ. 50 mA
  • Protective circuit
    Surge protection Suppressor diode
  • Max. permissible overall conductor resistance
    150 Ί
  • Height
    116.6 mm
  • Ambient temperature (operation)
    -35 °C ... 60 °C (observe derating)
  • Rated control circuit supply voltage US
    24 V DC -20 % / +25 %
  • Input name
    Start circuit
  • Input current range "0" signal
    0 mA ... 2 mA
  • Output name
    Enabling current paths
  • Switching capacity
    min. 60 mW
  • Current
    max. 100 mA
  • Nominal operating mode
    100% operating factor
  • Min. degree of protection of inst. location
    IP54
  • Conductor cross section solid
    0.2 mm² ... 1.5 mm²
  • Performance level (PL)
    c (up to PL e depending on the application)
  • Concurrence
    ∞
  • Category
    1 (up to Cat. 3 depending on the application)
  • Rated surge voltage/insulation
    Basic insulation 4 kV: between all current paths and housingSafe isolation, reinforced insulation 6 kV:between (A1, A2, S11, S12, S21, S22, S34, M1) and enabling current path (13/14)between (A1, A2, S11, S12, S21, S22, S34, M1) and enabling current path (
  • Conformance
    CE-compliant
  • Depth
    114.5 mm
  • Max. permissible humidity (storage/transport)
    75 % (on average, 85% infrequently, non-condensing)
  • Designation
    Air clearances and creepage distances between the power circuits
  • Input voltage range "0" signal
    0 V DC ... 5 V DC
  • Contact type
    2 enabling current paths
  • Voltage
    approx. 23 V DC (US - 1 V)
  • Short-circuit protection
    Yes
  • Relay type
    Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Maximum altitude
    ≤ 2000 m (Above sea level)
  • Power consumption at US
    typ. 1.2 W
  • Filter time
    max. 3 ms (Test pulse width of low test pulses)
  • Number of inputs
    1
  • Current consumption
    < 3.2 mA (typically with US)
  • Output description
    PNP
  • Switching voltage
    min. 12 V AC/DC
  • Limiting continuous current
    6 A (observe derating)
  • Maximum inrush current
    500 mA (Δt = 1 ms at Us)
  • Delay time range
    0.2 s ... 60 s ¹5 % (can be set for 27/28)
  • Mounting position
    vertical or horizontal
  • Degree of protection
    IP20
  • Connection method
    Push-in connection
  • Conductor cross-section flexible with ferrule and plastic sleeve
    0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
  • Conductor cross-section AWG
    24 ... 16
  • Stop category
    1
  • Vibration (operation)
    10 Hz ... 150 Hz, 2g
  • ECLASS 11.0
    27371819
  • ECLASS 5.1
    27371900
  • ECLASS 7.0
    27371819
  • UNSPSC 20.0
    39122205
  • Inrush current
    min. 3 mA
  • Description of the input
    non-safety-related
  • Limit frequency
    min. 0 Hz
  • Mechanical service life
    10x 106 cycles
  • Typical response time at US
    < 35 ms (automatic start)
  • Restart time
    < 1 s (Boot time)
  • Net weight
    126.6 g
  • Housing material
    PBT
  • pluggable
    Yes
  • Stripping length
    8 mm
  • Safety Integrity Level Claim Limit (SIL CL)
    1 (up to SILCL 3 depending on the application)
  • Rated insulation voltage
    250 V AC
  • ECLASS 4.0
    40020600
  • ECLASS 5.0
    27371900
  • ECLASS 9.0
    27371819
  • UNSPSC 13.2
    39121501
  • UNSPSC 21.0
    39122205
  • Sq. Total current
    72 A2 (observe derating)
  • Output fuse
    6 A gL/gG (N/O contact)
  • Typical release time at US
    < 20 ms (when controlled via S12 (only for undelayed contact 13/14))
  • Assembly instructions
    See derating curve
  • Housing color
    yellow
  • Conductor cross-section flexible with ferrule without plastic sleeve
    0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
  • Degree of pollution
    2
  • Shock
    15g
  • ECLASS 10.0.1
    27371819
  • ETIM 6.0
    EC001449
  • Mounting type
    DIN rail mounting
  • Status display
    5 x bi-color LED
  • Conductor cross section flexible
    0.2 mm² ... 1.5 mm²
  • Safety Integrity Level (SIL)
    1 (up to SIL 3 depending on the application)
  • Standards/regulations
    DIN EN 50178
  • Overvoltage category
    III
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 6.0
    27371800
  • UNSPSC 18.0
    39122205
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    40020600
  • ETIM 7.0
    EC001449
  • UNSPSC 19.0
    39122205

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?