2702094 Phoenix Contact Electrical Safety Devices
Part#:2702094
Manufacturer:Phoenix Contact
Category:Electrical Safety Devices
Product Lifecycle:Active
Get a quick Quote!
Safety relay for emergency stop, safety doors, light grid up to SILCL 1, Cat. 1, PL c, 1- or 2-channel operation, cross-circuit detection, can be retriggered, off delay/on delay 0.2 s to 60 s, 2 enabling current paths, US = 24 V DC, plug-in screw terminal
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2702094 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth 114.5 mm
- Height 112.2 mm
- Rated control circuit supply voltage US 24 V DC -20 % / +25 %
- Filter time max. 3 ms (Test pulse width of low test pulses)
- Width 12.5 mm
- Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
- Rated control supply current IS typ. 50 mA
- Protective circuit Surge protection Suppressor diode
- Input current range "0" signal 0 mA ... 2 mA
- Limit frequency min. 0 Hz
- Mechanical service life 10x 106 cycles
- Typical release time at US < 20 ms (when controlled via S12 (only for undelayed contact 13/14))
- Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Housing material PBT
- pluggable Yes
- Screw thread M3
- Safety Integrity Level Claim Limit (SIL CL) 1 (up to SILCL 3 depending on the application)
- Standards/regulations DIN EN 50178
- ECLASS 10.0.1 27371819
- ECLASS 4.0 40020600
- ECLASS 5.1 27371900
- UNSPSC 19.0 39122205
- Ambient temperature (operation) -35 °C ... 60 °C (observe derating)
- Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
- Designation Air clearances and creepage distances between the power circuits
- Input name Start circuit
- Current consumption < 3.2 mA (typically with US)
- Concurrence ∞
- Contact material AgSnO2
- Output fuse 6 A gL/gG (N/O contact)
- Current max. 100 mA
- Nominal operating mode 100% operating factor
- Degree of protection IP20
- Housing color yellow
- Stripping length 7 mm
- Category 1 (up to Cat. 3 depending on the application)
- Rated surge voltage/insulation Basic insulation 4 kV: between all current paths and housingSafe isolation, reinforced insulation 6 kV:between (A1, A2, S11, S12, S21, S22, S34, M1) and enabling current path (13/14)between (A1, A2, S11, S12, S21, S22, S34, M1) and enabling current path (
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 9.0 27371819
- ETIM 7.0 EC001449
- UNSPSC 20.0 39122205
- Power consumption at US typ. 1.2 W
- Input voltage range "0" signal 0 V DC ... 5 V DC
- Output name Enabling current paths
- Limiting continuous current 6 A (observe derating)
- Maximum inrush current 500 mA (Δt = 1 ms at Us)
- Restart time < 1 s (Boot time)
- Net weight 115.153 g
- Assembly instructions See derating curve
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Conductor cross-section AWG 24 ... 12
- Rated insulation voltage 250 V AC
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 40020600
- ECLASS 6.0 27371800
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Maximum altitude ≤ 2000 m (Above sea level)
- Inrush current min. 3 mA
- Number of inputs 1
- Number of outputs 1
- Switching capacity min. 60 mW
- Sq. Total current 72 A2 (observe derating)
- Typical response time at US < 35 ms (automatic start)
- Mounting type DIN rail mounting
- Min. degree of protection of inst. location IP54
- Connection method Screw connection
- Stop category 1
- Performance level (PL) c (up to PL e depending on the application)
- Overvoltage category III
- Shock 15g
- Conformance CE-compliant
- ECLASS 5.0 27371900
- ETIM 6.0 EC001449
- UNSPSC 21.0 39122205
- Description of the input non-safety-related
- Max. permissible overall conductor resistance 150 Ω
- Output description PNP
- Contact type 2 enabling current paths
- Switching voltage min. 12 V AC/DC
- Voltage approx. 23 V DC (US - 1 V)
- Short-circuit protection Yes
- Delay time range 0.2 s ... 60 s ±5 % (can be set for 27/28)
- Mounting position vertical or horizontal
- Status display 5 x bi-color LED
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Safety Integrity Level (SIL) 1 (up to SIL 3 depending on the application)
- Degree of pollution 2
- ECLASS 11.0 27371819
- ECLASS 7.0 27371819
- UNSPSC 13.2 39121501
- UNSPSC 18.0 39122205
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.