2702068 Phoenix Contact Programmable Logic Controllers
Part#:2702068
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline F, Digital output module, Digital outputs: 4 (Triac outputs with zero voltage switch), 230 V AC, 2 A AC, connection method: 3-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axio
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2702068 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Color traffic grey A RAL 7042
- Supply voltage 230 V AC
- Output name Digital outputs
- Supply voltage range 12 V AC ... 253 V AC (including all tolerances, including ripple, 50 ... 60 Hz)
- Nominal output voltage 230 V AC
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion A, AC and OUT supply lines: ±2 kV/±4 kV (symmetrical/asymmetrical)
- Developed according to standard IEC 61850-3 Immunity to magnetic fields, EN 61000-4-8/IEC 61000-4-8 300 A/m continuous, 1000 A/m for 1 s
- China RoHS Environmentally Friendly Use Period = 50 years
- UNSPSC 19.0 32151602
- Conductor cross section AWG max. 16
- Degree of protection IP20
- Conductor cross section flexible max. 1.5 mm²
- Power consumption max. 2024 VA (of which 8 VA internal losses)
- Connection technology 3-conductor
- Output voltage when switched off see diagram
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, 20 V/m
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- ECLASS 5.1 27242600
- UNSPSC 13.2 32151602
- Designation Supply for digital output modules (UO)
- Conductor cross section solid min. 0.5 mm²
- Conductor cross section AWG min. 20
- Note on weight specifications with connectors and bus base module
- Protective circuit External protection required I2t-value (a half-wave): 340 A2s
- Number of outputs 4 (Triac outputs with zero voltage switch)
- Load min. 5.1 kΩ (at 230 V)
- Reverse voltage resistance to short pulses Reverse voltage proof
- ECLASS 6.0 27242600
- ETIM 7.0 EC001599
- ETIM 6.0 EC001599
- UNSPSC 20.0 32151602
- Connection method Push-in connection
- Conductor cross section solid max. 1.5 mm²
- Stripping length 8 mm
- Number 2
- Height 126.1 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Protection max. 8 A
- Output voltage 230 V AC
- Nominal load, ohmic max. 460 W (at nominal voltage)
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Test section I/Os / logic 4 kV Rated surge voltage (safe isolation according to EN 61010-2-201/IEC 61010-2-201)
- ECLASS 11.0 27242604
- ECLASS 7.0 27242604
- UNSPSC 18.0 32151602
- UNSPSC 21.0 32151602
- Depth 54 mm
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.When selecting the cables, please note that in the case of a small conductor cross section and high current, the terminal point te
- Conductor cross section flexible min. 0.5 mm²
- Mounting type DIN rail
- Current consumption max. 8 A (provide external protection)
- Switching frequency max. 100 per second (with ohmic load)
- Behavior with overload Output may be damaged
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 10.0.1 27242604
- Mounting position any (observe temperature and current derating)
- ECLASS 9.0 27242604
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Transmission speed 100 Mbps
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Ambient temperature (operation) -25 °C ... 60 °C (max. 2 A/channel for wall mounting on horizontal DIN rail; max. 1 A/channel for any mounting position)
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, 2.5 kV, criterion B, 4 kV
- Width 53.6 mm
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Net weight 239 g
- REACh SVHC Lead 7439-92-1
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?