2702017 Phoenix Contact Programmable Logic Controllers
Part#:2702017
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline F XC, Digital I/O module, Digital inputs: 8, 24 V DC, connection method: 1-conductor, Digital outputs: 8, 24 V DC, 500 mA, connection method: 1-conductor, Extreme conditions version, transmission speed in the local bus: 100 Mbps, degree of protec
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2702017 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Output name Digital outputs
- Input voltage range "0" signal -3 V DC ... 5 V DC
- Output voltage 24 V DC
- Nominal load, ohmic max. 12 W (48 Ω, with nominal voltage)
- Load min. 10 kΩ
- Ambient temperature (operation) -25 °C ... 60 °C (Standard, applications with UL approval, use in zone 2 potentially explosive area)
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Conductor cross section solid max. 1.5 mm²
- Color traffic grey A RAL 7042
- Transmission speed 100 Mbps
- Current consumption max. 4 A (provide external protection)
- Description of the input EN 61131-2 types 1 and 3
- Nominal input voltage UIN 24 V DC
- Mounting type DIN rail
- Supply voltage 24 V DC
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Input name Digital inputs
- Protection max. 8 A (polarity reversal protection up to 5 A)
- Reverse voltage resistance to short pulses limited protection up to 0.5 A for 1 s
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Connection method Push-in connection
- Conductor cross section flexible min. 0.2 mm²
- Number of outputs 8
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Switching frequency max. 10000 per second (with at least 50 mA load current)
- Conductor cross section AWG min. 24
- Net weight 133 g
- Note on weight specifications with connectors and bus base module
- Overvoltage category II (IEC 60664-1, EN 60664-1)
- ETIM 6.0 EC001599
- UNSPSC 20.0 32151602
- Power consumption max. 96 W (of which 1.35 W internal losses)
- Protective circuit Short-circuit protection, overload protection of the outputs electronic
- Depth 54 mm
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- Number of inputs 8
- Nominal input current at UIN 2.4 mA
- Nominal output voltage 24 V DC
- Output voltage when switched off max. 1 V
- Behavior with inductive overload Output can be destroyed
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Designation Supply for digital input and output modules (UIO)
- Conductor cross section flexible max. 1.5 mm²
- Behavior with overload Shutdown with automatic restart
- ATEX II 3 G Ex ec IIC T4 Gc
- REACh SVHC Lead 7439-92-1
- ECLASS 5.1 27242600
- UNSPSC 13.2 32151602
- Degree of pollution 2 (IEC 60664-1, EN 60664-1)
- Mounting position any (no temperature derating)
- Number of interfaces 2
- Width 35 mm
- Height 126.1 mm
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Degree of protection IP20
- Connection technology 1-conductor
- Input filter time 3000 µs (Default)
- Nominal load, lamp max. 12 W (at nominal voltage)
- Nominal load, inductive max. 12 VA (1.2 H, 48 Ω, with nominal voltage)
- Output current when switched off max. 300 µA
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG max. 16
- Stripping length 8 mm
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 7.0 27242604
- ECLASS 6.0 27242600
- UNSPSC 18.0 32151602
- UNSPSC 21.0 32151602
- Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- IECEx Ex ec IIC T4 Gc
- ECLASS 10.0.1 27242604
- ETIM 7.0 EC001599
- UNSPSC 19.0 32151602
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- UL, USA/Canada cULus
- ECLASS 9.0 27242604
- ECLASS 11.0 27242604
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?