2702008 Phoenix Contact Programmable Logic Controllers
Part#:2702008
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline F XC, Analog input module, Analog inputs: 4, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, connection method: 2-, 3-, 4-conductor, transmission speed in the local bus: 100 Mbps, integrated sensor supply, Extreme conditions version, deg
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2702008 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 35 mm
- Depth 54 mm
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Degree of protection IP20
- Connection method Push-in connection
- Conductor cross section flexible max. 1.5 mm²
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG max. 16
- Color traffic grey A RAL 7042
- Note on weight specifications with connectors and bus base module
- Mounting position any (no temperature derating)
- Current consumption max. 45 mA (IiS = 0 mA)
- Number of interfaces 2
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Protective circuit Surge protection electronic (35 V, 0.5 s)
- Number of inputs 4
- Height 126.1 mm
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Designation Supply for analog modules (UA)
- Conductor cross section flexible min. 0.2 mm²
- Limit frequency (3 dB) 30 Hz
- Note regarding the connection technology shielded, twisted pair
- Measured value representation 16 bits (15 bits + sign bit)
- Voltage input signal 0 V ... 5 V
- Input resistance of voltage input 268 kΩ (typical)
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- Conductor cross section AWG min. 24
- Conductor cross section solid max. 1.5 mm²
- Stripping length 8 mm
- Degree of pollution 2 (IEC 60664-1, EN 60664-1)
- Net weight 215 g
- Transmission speed 100 Mbps
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- UL, USA/Canada cULus
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 10.0.1 27242601
- ECLASS 5.1 27242600
- ECLASS 6.0 27242600
- ETIM 7.0 EC001596
- Supply voltage 24 V DC (I/O supply and sensor supply)
- Power consumption max. 5.88 W (Full load)
- Description of the input Differential inputs, voltage
- Input name Analog inputs
- A/D converter resolution 16 bit
- UNSPSC 20.0 32151602
- A/D conversion time 31.25 µs
- Type of protection Transient protection of inputs
- Data formats IB IL, S7-compatible
- Common mode voltage range signal - ground -50 V DC ... 50 V DC
- Input filter 30 Hz, 12 kHz and mean-value generation (can be parameterized)
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ATEX II 3 G Ex ec IIC T4 Gc
- REACh SVHC Lead 7439-92-1
- Overvoltage category II (IEC 60664-1, EN 60664-1)
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- IECEx Ex ec IIC T4 Gc
- ECLASS 7.0 27242601
- ECLASS 11.0 27242601
- Mounting type DIN rail
- Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Ambient temperature (operation) -25 °C ... 60 °C (Standard, applications with UL approval, use in zone 2 potentially explosive area)
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 up to HW 02: Criterion B,DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables
- Connection technology 2-, 3-, 4-conductor
- UNSPSC 18.0 32151602
- UNSPSC 21.0 32151602
- UNSPSC 19.0 32151602
- ECLASS 9.0 27242601
- ETIM 6.0 EC001596
- UNSPSC 13.2 32151602
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?