Axioline F XC, Communication module, interface: RS-232, RS-485, RS-422, Extreme conditions version, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2702006 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000Â m above sea level)
- Caption Dimensional drawing
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Note on the connection method Please observe the information provided on conductor cross sections in the âAxioline F: system and installationâ user manual.
- Stripping length 8 mm
- Color traffic grey A RAL 7042
- Transmission speed 100 Mbps
- Stop bits 1 or 2
- Power consumption typ. 1 W
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section AWG min. 24
- Termination resistor active, integrated
- Protocols supported Transparent, end-to-end, XON/XOFF, Modbus/RTU (master support)
- Output buffer 1 kByte
- Parity Even, odd or no parity
- ETIM 7.0 EC001604
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields ENÂ 61000-4-3/IECÂ 61000-4-3 Criterion A, Field intensity: 10 V/m
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27242608
- UNSPSC 20.0 32151602
- Width 35 mm
- Note on dimensions The depth is valid when a THÂ 35-7,5 DIN rail is used (according to ENÂ 60715).
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000Â m above sea level)
- Designation Axioline F local bus supply (UBus)
- Conductor cross section flexible max. 1.5 mm²
- Mounting type DIN rail
- Number of interfaces 1
- Input buffer 4 kByte
- Current consumption typ. 200 mA
- Test section 5Â V supply of the local bus (UBus) / 5Â V supply (I/Os) 1000 VÂ DC 1 min.
- ATEX ď II 3 G Ex ec IIC T4 Gc
- Protection class III (IECÂ 61140, ENÂ 61140, VDEÂ 0140-1)
- ECLASS 10.0.1 27242608
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Depth 54 mm
- Ambient temperature (operation) -25 °C ... 60 °C (Standard, applications with UL approval, use in zone 2 potentially explosive area)
- Connection method Push-in connection
- Conductor cross section solid max. 1.5 mm²
- Conductor cross section AWG max. 16
- Note on weight specifications with connectors and bus base module
- Mounting position any (no temperature derating)
- Transmission physics Copper
- Transmission type Transparent mode, end-to-end mode, XON/XOFF, Modbus/RTU
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) ENÂ 61000-4-4/IECÂ 61000-4-4 Criterion B, 2Â kV
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- China RoHS Environmentally Friendly Use Period = 50 years
- Height 126.1 mm
- Degree of protection IP20
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Conductor cross section solid min. 0.2 mm²
- Net weight 187.4 g
- Degree of pollution 2 (IECÂ 60664-1, ENÂ 60664-1)
- Data bits 5 ... 8
- Supply voltage 5 VÂ DC (via bus base module)
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) ENÂ 61000-4-5/IECÂ 61000-4-5 Criterion B, DC supply lines: Âą0.5 kV/Âą0.5 kV (symmetrical/asymmetrical)
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) ENÂ 61000-4-2/IECÂ 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference ENÂ 61000-4-6/IECÂ 61000-4-6 Criterion A, Test voltage 10 V
- Overvoltage category II (IECÂ 60664-1, ENÂ 60664-1)
- ECLASS 7.0 27242608
- ETIM 6.0 EC001604
- ECLASS 5.1 27242600
- UNSPSC 18.0 32151602
- UNSPSC 19.0 32151602
- Mechanical tests Vibration resistance in acc. with ENÂ 60068-2-6/IECÂ 60068-2-6 5g
- IECEx Ex ec IIC T4 Gc
- UNSPSC 13.2 32151602
- UNSPSC 21.0 32151602
- UL, USA/Canada cULus
- ECLASS 6.0 27242600
- ECLASS 9.0 27242608
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?