2701686 Phoenix Contact Programmable Logic Controllers
Part#:2701686
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline F, Bus coupler, Sercos, RJ45 jack, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connector
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701686 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Degree of protection IP20
- Conductor cross section AWG min. 24
- Conductor cross section flexible max. 1.5 mm²
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Mounting position any (observe temperature derating)
- Transmission speed 100 Mbps
- Device profile FSP_IO
- Ambient temperature (operation) -25 °C ... 60 °C (Mounting position: wall mounting on horizontal DIN rail)
- Designation Axioline F local bus supply (UBus)
- Conductor cross section flexible min. 0.2 mm²
- Mounting type DIN rail mounting
- Width 45 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Protocol Sercos
- Depth 74 mm
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Connection method Micro USB type B
- Conductor cross section solid max. 1.5 mm²
- Stripping length 8 mm
- ETIM 4.0 EC001604
- UNSPSC 6.01 43172015
- UNSPSC 12.01 39121311
- Net weight 177 g
- Number of interfaces 1
- Specification Sercos specification 1.31
- Current consumption max. 570 mA (with 2 A at UBus for the I/Os and UL = 24 V)
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 10.0.1 27242608
- ECLASS 6.0 27242600
- Height 126.1 mm
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Note on the connection method Auto negotiation and autocrossing
- Conductor cross section AWG max. 16
- Degree of pollution 2 (IEC 60664-1, EN 60664-1)
- Transmission physics Ethernet in RJ45 twisted pair
- Number of local bus devices that can be connected max. 63
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- ECLASS 7.0 27242608
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Conductor cross section solid min. 0.2 mm²
- Color traffic grey A RAL 7042
- Equipment type Sercos slave
- Supply voltage 5 V DC (via bus base module)
- Type of protection Surge protection
- Overvoltage category II (IEC 60664-1, EN 60664-1)
- ECLASS 11.0 27242608
- ECLASS 9.0 27242608
- Note on weight specifications with connector and bus base module
- Number of supported devices max. 63 (per station)
- System-specific protocols Sercos protocols Sercos
- Power consumption max. 13.7 W (2.0 A on UBus, UL = 24 V)
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- ECLASS 4.0 27240400
- ECLASS 5.0 27242200
- ECLASS 5.1 27242600
- ETIM 3.0 EC001604
- UNSPSC 7.0901 43201404
- UNSPSC 18.0 32151602
- UNSPSC 21.0 32151602
- Power supply unit 2 A
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- REACh SVHC Lead 7439-92-1
- UNSPSC 19.0 32151602
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- UNSPSC 13.2 32151602
- UNSPSC 20.0 32151602
- ETIM 6.0 EC001604
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
- ECLASS 4.1 27240400
- ETIM 7.0 EC001604
- China RoHS Environmentally Friendly Use Period = 50 years
- UNSPSC 11 39121311
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?