2701550 Phoenix Contact Programmable Logic Controllers
Part#:2701550
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline E, Digital I/O device, Sercos, M12 fast connection technology, Digital inputs: 16, 24 V DC, connection method: 4-conductor, Digital outputs: 16, 24 V DC, 500 mA, connection method: 3-conductor, Metal housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701550 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth 38 mm
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Permissible humidity (operation) 5 % ... 95 %
- Net weight 706.6 g
- Number of outputs 16
- Width 60 mm
- Drill hole spacing 198.5 mm
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Housing material Zinc die-cast
- Connection method M12 connector, double occupancy
- Note on the connection method D-coded
- Height 185 mm
- Permissible humidity (storage/transport) 5 % ... 95 %
- Degree of protection IP65/IP67
- ECLASS 10.0.1 27242604
- ECLASS 4.1 27240400
- ECLASS 7.0 27242604
- ECLASS 5.1 27242600
- Number 2
- Mounting type Wall mounting or DIN rail mounting; both with mounting plate.
- Designation connection point Copper cable
- Device profile FSP_IO
- Specification Sercos specification 1.1.2
- Input name Digital inputs
- Note on dimensions The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Current consumption typ. 3 mA ±15 % (at 24 V DC)
- Number of inputs 16
- Input filter time < 1000 µs
- Output voltage 24 V DC
- Output voltage when switched off max. 1 V
- China RoHS Environmentally Friendly Use Period = 25;
- Ambient temperature (operation) -25 °C ... 60 °C
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Designation Actuators (UA) for additional devices
- Transmission speed 100 Mbps (with auto negotiation)
- System-specific protocols Sercos protocols Sercos
- Equipment type Sercos slave
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Connection technology 3-conductor
- Nominal input voltage UIN 24 V DC
- Nominal input current at UIN typ. 3 mA
- Nominal load, inductive 12 VA (1.2 H, 48 Ω, with nominal voltage)
- Output name Digital outputs
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- REACh SVHC Lead 7439-92-1
- ECLASS 4.0 27240400
- ECLASS 5.0 27242200
- ETIM 3.0 EC001599
- UNSPSC 6.01 43172015
- UNSPSC 19.0 32151602
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 11.0 27242604
- UNSPSC 12.01 39121311
- UNSPSC 20.0 32151602
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 6.0 27242600
- ETIM 2.0 EC001433
- ETIM 6.0 EC001599
- UNSPSC 13.2 32151602
- UNSPSC 21.0 32151602
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- ECLASS 9.0 27242604
- UNSPSC 18.0 32151602
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Reverse voltage resistance to short pulses Reverse voltage proof
- ETIM 7.0 EC001599
- Switching frequency max. 5500 per second (with at least 50 mA load current)
- Test section 24 V supply (communications power/sensor supply, digital inputs/outputs)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
- UNSPSC 7.0901 43201404
- Number of positions 4
- Description of the input EN 61131-2 types 1 and 3
- Protective circuit Overload protection, short-circuit protection of outputs yes
- Nominal output voltage 24 V DC (from voltage US)
- Output current when switched off max. 20 µA
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- ETIM 4.0 EC001599
- Protocols supported HTTP
- Supply voltage 24 V DC
- Nominal load, ohmic 12 W (48 Ω, with nominal voltage)
- Behavior with overload Auto restart
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Input voltage range "0" signal 0 V ... 5 V DC
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- UNSPSC 11 39121311
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty