Axioline E, Digital input device, Sercos, M12 fast connection technology, Digital inputs: 16, 24 V DC, connection method: 4-conductor, Metal housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701549 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Note on dimensions The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
- Permissible humidity (operation) 5 % ... 95 %
- Mounting type Wall mounting or DIN rail mounting; both with mounting plate.
- Connection method M12 connector, double occupancy
- Specification Sercos specification 1.1.2
- Supply voltage 24 V DC
- Connection technology 4-conductor
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- REACh SVHC Lead 7439-92-1
- ECLASS 5.0 27242200
- ECLASS 9.0 27242604
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Drill hole spacing 198.5 mm
- Permissible humidity (storage/transport) 5 % ... 95 %
- Degree of protection IP65/IP67
- Designation connection point Copper cable
- Equipment type Sercos slave
- Current consumption typ. 3 mA ±15 % (at 24 V DC)
- Nominal input voltage UIN 24 V DC
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 11.0 27242604
- ETIM 3.0 EC001599
- ETIM 4.0 EC001599
- UNSPSC 19.0 32151602
- Width 60 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Designation Actuators (UA) for additional devices
- Device profile FSP_IO
- Number of positions 4
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Number of inputs 16
- Input voltage range "0" signal 0 V ... 5 V DC
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 5.1 27242600
- ECLASS 7.0 27242604
- ETIM 2.0 EC001433
- UNSPSC 12.01 39121311
- UNSPSC 21.0 32151602
- Height 185 mm
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Housing material Zinc die-cast
- Number 2
- Transmission speed 100 Mbps (with auto negotiation)
- System-specific protocols Sercos protocols Sercos
- Protective circuit Overload protection, short-circuit protection of sensor supply
- Nominal input current at UIN typ. 3 mA
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- ECLASS 10.0.1 27242604
- ECLASS 4.1 27240400
- ETIM 6.0 EC001599
- UNSPSC 13.2 32151602
- UNSPSC 7.0901 43201404
- Depth 38 mm
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Net weight 703 g
- Note on the connection method D-coded
- Protocols supported HTTP
- Input name Digital inputs
- Description of the input EN 61131-2 types 1 and 3
- ECLASS 4.0 27240400
- UNSPSC 6.01 43172015
- UNSPSC 18.0 32151602
- Input filter time < 1000 µs
- Test section 24 V supply (communications power and sensor supply, digital inputs)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- UNSPSC 11 39121311
- UNSPSC 20.0 32151602
- ECLASS 6.0 27242600
- ETIM 7.0 EC001599
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?