2701534 Phoenix Contact Programmable Logic Controllers
Part#:2701534
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline E, Digital I/O device, Ethernet, M12 fast connection technology, Digital inputs: 16, 24 V DC, connection method: 4-conductor, Digital outputs: 16, 24 V DC, 500 mA, connection method: 3-conductor, Plastic housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701534 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 60 mm
- Note on dimensions The height is 212 mm including fixing clips.
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Mounting type Wall mounting
- ECLASS 4.0 27240400
- Permissible humidity (storage/transport) 5 % ... 95 %
- Housing material Pocan®
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Net weight 558.4 g
- Designation connection point Copper cable
- Transmission speed 10/100 Mbps (with auto negotiation)
- Description of the input EN 61131-2 types 1 and 3
- Nominal input voltage UIN 24 V DC
- Nominal input current at UIN typ. 3 mA
- Switching frequency max. 5500 per second (with at least 50 mA load current)
- ECLASS 6.0 27242600
- Color anthracite
- Number of positions 4
- Supply voltage 24 V DC
- Connection technology 3-conductor
- Input voltage range "0" signal 0 V ... 5 V DC
- Output voltage 24 V DC
- Nominal output voltage 24 V DC (from voltage US)
- Output voltage when switched off max. 1 V
- ECLASS 11.0 27242604
- Drill hole spacing 198.5 mm
- Degree of protection IP65/IP67
- Height 185 mm
- Permissible humidity (operation) 5 % ... 95 %
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Designation Actuators (UA) for additional devices
- Number 2
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 5.0 27242200
- Depth 30.5 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Note on the connection method D-coded
- System-specific protocols Modbus protocols Modbus/TCP
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- ECLASS 5.1 27242600
- Specification Modbus application protocol V1.1b
- Number of inputs 16
- Input filter time < 1000 µs
- Number of outputs 16
- Nominal load, inductive 12 VA (1.2 H, 48 Ω, with nominal voltage)
- ECLASS 4.1 27240400
- Connection method M12 connector, double occupancy
- Equipment type Modbus slave (server)
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Current consumption typ. 3 mA ±15 % (at 24 V DC)
- Test section 24 V supply (communications power/sensor supply, digital inputs/outputs)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
- REACh SVHC Lead 7439-92-1
- Cable length max. 30 m (To the sensor)
- Output current when switched off max. 20 µA
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 7.0 27242604
- ETIM 4.0 EC001599
- UNSPSC 13.2 32151602
- UNSPSC 18.0 32151602
- Protective circuit Overload protection, short-circuit protection of outputs yes
- Behavior with overload Auto restart
- UNSPSC 11 39121311
- UNSPSC 19.0 32151602
- Nominal load, ohmic 12 W (48 Ω, with nominal voltage)
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ETIM 3.0 EC001599
- UNSPSC 12.01 39121311
- ECLASS 10.0.1 27242604
- Reverse voltage resistance to short pulses Reverse voltage proof
- UNSPSC 6.01 43172015
- ETIM 2.0 EC001433
- ETIM 7.0 EC001599
- UNSPSC 20.0 32151602
- Input name Digital inputs
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Protocols supported SNMP v1
- ECLASS 9.0 27242604
- UNSPSC 21.0 32151602
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- ETIM 6.0 EC001599
- Output name Digital outputs
- UNSPSC 7.0901 43201404
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?