2701525 Phoenix Contact Programmable Logic Controllers
Part#:2701525
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline E, Digital I/O device, EtherCAT®, M12 fast connection technology, Digital inputs: 8, 24 V DC, connection method: 4-conductor, Digital outputs: 8, 24 V DC, 500 mA, connection method: 3-conductor, Metal housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701525 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- ECLASS 7.0 27242604
- ETIM 4.0 EC001599
- ECLASS 4.0 27240400
- UNSPSC 7.0901 43201404
- UNSPSC 19.0 32151602
- Depth 38 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Net weight 722.8 g
- Note on the connection method D-coded
- Type of addressing Auto-increment addressing
- Current consumption typ. 30 mA ±15 % (at 24 V DC)
- Protective circuit Overload protection, short-circuit protection of outputs yes
- Nominal input voltage UIN 24 V DC
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- Output name Digital outputs
- ECLASS 10.0.1 27242604
- UNSPSC 12.01 39121311
- UNSPSC 20.0 32151602
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Drill hole spacing 198.5 mm
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Connection method M12 connector, double occupancy
- Designation connection point Copper cable
- Input name Digital inputs
- Connection technology 3-conductor
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Width 60 mm
- Degree of protection IP65/IP67
- Number 2
- System-specific protocols Mailbox protocols CANopen® over EtherCAT®
- Equipment type EtherCAT® slave
- Number of inputs 8
- Nominal input current at UIN typ. 3 mA
- Nominal output voltage 24 V DC (from voltage UA)
- Output voltage when switched off max. 1 V
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27242604
- UNSPSC 11 39121311
- UNSPSC 13.2 32151602
- Input filter time < 1000 µs
- Number of outputs 8
- Output current when switched off max. 20 µA
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- China RoHS Environmentally Friendly Use Period = 25;
- Height 185 mm
- Permissible humidity (operation) 5 % ... 95 %
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Mounting type Wall mounting or DIN rail mounting; both with mounting plate.
- Number of positions 4
- Supply voltage 24 V DC
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- ETIM 2.0 EC001433
- ETIM 6.0 EC001599
- ETIM 7.0 EC001599
- UNSPSC 21.0 32151602
- Designation Actuators (UA)
- Transmission speed 100 Mbps (with auto negotiation)
- Specification ETG.1000 V1.02
- Description of the input EN 61131-2 types 1 and 3
- Input voltage range "0" signal 0 V ... 5 V DC
- Output voltage 24 V DC
- ETIM 3.0 EC001599
- UNSPSC 6.01 43172015
- UNSPSC 18.0 32151602
- Note on dimensions The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
- Permissible humidity (storage/transport) 5 % ... 95 %
- Housing material Zinc die-cast
- ECLASS 4.1 27240400
- Behavior with overload Auto restart
- Reverse voltage resistance to short pulses Reverse voltage proof
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 5.0 27242200
- Nominal load, inductive 12 VA (1.2 H, 48 Ω, with nominal voltage)
- ECLASS 9.0 27242604
- Test section 24 V supply (communications power and sensor supply, digital inputs)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
- ECLASS 6.0 27242600
- Nominal load, ohmic 12 W (48 Ω, with nominal voltage)
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- Switching frequency max. 5500 per second (with at least 50 mA load current)
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 5.1 27242600
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?