2701524 Phoenix Contact Programmable Logic Controllers
Part#:2701524
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline E-EtherCAT® device in a plastic housing with 8 IO-Link ports and 4 digital inputs, 24 V DC, M12 fast connection technology
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701524 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Designation Actuators (UA)
- Height 185 mm
- Permissible humidity (operation) 5 % ... 95 %
- Degree of protection IP65/IP67
- Note on dimensions The height is 212 mm including fixing clips.
- Nominal output voltage 24 V DC
- Output voltage when switched off max. 1 V
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Color anthracite
- Note on the connection method D-coded
- Equipment type EtherCAT® slave
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Nominal input voltage UIN 24 V DC
- Nominal input current at UIN typ. 3 mA
- Type of protection Overload protection
- Test section 24 V supply (communications power and sensor supply, IO-Link ports)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
- ECLASS 4.1 27240400
- Depth 30.5 mm
- Input name Digital inputs at pin 2 for type A ports
- Number of inputs max. 8 (EN 61131-2 type 1)
- Input filter time < 1000 µs
- Number of outputs max. 8
- ECLASS 11.0 27242604
- Connection technology 3-conductor
- Input voltage range "1" signal 15 V DC ... 30 V DC
- Nominal input current typ. 3 mA
- Output description IO-Link ports in digital output (DO) mode
- Switching rate 1 per second, maximum (at nominal inductive load)
- Behavior with overload Shutdown with automatic restart
- ECLASS 4.0 27240400
- ETIM 2.0 EC001433
- UNSPSC 6.01 43172015
- UNSPSC 12.01 39121311
- System-specific protocols Mailbox protocols CANopen® over EtherCAT®
- Current consumption typ. 28 mA ±15 % (at 24 V DC)
- Input voltage range "0" signal -0.3 V DC ... 5 V DC
- Sensor current per channel max. 200 mA (from L+/L-)
- Nominal load, ohmic 3.6 W (160 Ω, at nominal load)
- Signal delay max. 150 µs (when switched on)
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- Total sensor current max. 1.6 A (from L+/L-)
- Maximum output current per device 1.2 A
- Limitation of the voltage induced on circuit interruption -15 V DC
- ECLASS 10.0.1 27242604
- ECLASS 6.0 27242600
- ETIM 7.0 EC001599
- UNSPSC 20.0 32151602
- Description of the input IO-Link ports in digital input (DI) mode
- Input frequency 0.5 kHz
- Net weight 551.4 g
- Number of positions 4
- Supply voltage 24 V DC
- Ambient temperature (operation) -25 °C ... 60 °C
- Housing material Pocan®
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Permissible humidity (storage/transport) 5 % ... 95 %
- Number 2
- Transmission speed 100 Mbps (with auto negotiation)
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Width 60 mm
- Type of addressing Auto-increment addressing
- ECLASS 5.1 27242600
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Designation connection point Copper cable
- Drill hole spacing 198.5 mm
- Specification ETG.1000 V1.02
- Connection method M12 connector, X01 ... X04 have double occupancy
- Protective circuit Overload protection, short-circuit protection of sensor supply
- Nominal load, inductive 3.6 VA (0.8 H, 160 Ω, at nominal load)
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- Mounting type Wall mounting
- Output current when switched off max. 300 µA
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- China RoHS Environmentally Friendly Use Period = 25;
- ETIM 3.0 EC001599
- ECLASS 5.0 27242200
- ECLASS 9.0 27242604
- Maximum output current per channel 150 mA
- UNSPSC 7.0901 43201404
- ECLASS 7.0 27242604
- UNSPSC 18.0 32151602
- UNSPSC 19.0 32151602
- ETIM 4.0 EC001599
- UNSPSC 11 39121311
- UNSPSC 13.2 32151602
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ETIM 6.0 EC001599
- UNSPSC 21.0 32151602
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?