Axioline E, Digital I/O device, PROFINET, M12 fast connection technology, Digital inputs: 16, 24 V DC, connection method: 4-conductor, Digital outputs: 16, 24 V DC, 500 mA, connection method: 3-conductor, Metal housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701517 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Input filter time < 1000 µs
- Note on dimensions The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
- Degree of protection IP65/IP67
- Designation Actuators (UA) for additional devices
- Number of supported application relationships (AR) 2
- Description of the input EN 61131-2 types 1 and 3
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- ECLASS 10.0.1 27242604
- ECLASS 4.1 27240400
- ECLASS 9.0 27242604
- Width 60 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Drill hole spacing 198.5 mm
- Housing material Zinc die-cast
- Number 2
- Note on the connection method D-coded
- Transmission speed 100 Mbps (with auto negotiation)
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 4.0 27240400
- ECLASS 7.0 27242604
- ETIM 4.0 EC001599
- UNSPSC 6.01 43172015
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- Height 185 mm
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Permissible humidity (storage/transport) 5 % ... 95 %
- Net weight 745 g
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- China RoHS Environmentally Friendly Use Period = 25;
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 5.0 27242200
- Nominal input voltage UIN 24 V DC
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Conformance class B
- System-specific protocols PROFINET protocols LLDP
- Nominal load, inductive 12 VA (1.2 H, 48 Ω, with nominal voltage)
- Reverse voltage resistance to short pulses Reverse voltage proof
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- REACh SVHC Lead 7439-92-1
- ECLASS 5.1 27242600
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Number of inputs 16
- Nominal output voltage 24 V DC (from voltage US)
- Nominal load, ohmic 12 W (48 Ω, with nominal voltage)
- Connection method M12 connector, double occupancy
- Number of positions 4
- Input name Digital inputs
- Nominal input current at UIN typ. 3 mA
- Designation connection point Copper cable
- Supply voltage 24 V DC
- Mounting type Wall mounting or DIN rail mounting; both with mounting plate.
- Depth 38 mm
- Equipment type PROFINET-Device
- Protocols supported SNMP v1
- ECLASS 11.0 27242604
- UNSPSC 7.0901 43201404
- UNSPSC 20.0 32151602
- UNSPSC 19.0 32151602
- Connection technology 3-conductor
- Protective circuit Overload protection, short-circuit protection of outputs yes
- Output voltage when switched off max. 1 V
- Number of outputs 16
- ETIM 2.0 EC001433
- UNSPSC 12.01 39121311
- Current consumption typ. 3 mA ±15 % (at 24 V DC)
- Output name Digital outputs
- Behavior with overload Auto restart
- UNSPSC 18.0 32151602
- ECLASS 6.0 27242600
- ETIM 6.0 EC001599
- ETIM 7.0 EC001599
- UNSPSC 13.2 32151602
- Input voltage range "0" signal 0 V ... 5 V DC
- Switching frequency max. 5500 per second (with at least 50 mA load current)
- Output current when switched off max. 20 µA
- UNSPSC 21.0 32151602
- Permissible humidity (operation) 5 % ... 95 %
- Cable length max. 30 m (To the sensor)
- Output voltage 24 V DC
- Test section 24 V supply (communications power/sensor supply, digital inputs/outputs)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
- ETIM 3.0 EC001599
- UNSPSC 11 39121311
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?