2701515 Phoenix Contact Programmable Logic Controllers
Part#:2701515
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline E, Digital I/O device, PROFINET, M12 fast connection technology, Digital inputs: 8, 24 V DC, connection method: 4-conductor, Digital outputs: 8, 24 V DC, 500 mA, connection method: 3-conductor, Metal housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701515 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Number of supported application relationships (AR) 2
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (operation) -25 °C ... 60 °C
- Permissible humidity (storage/transport) 5 % ... 95 %
- Degree of protection IP65/IP67
- Note on the connection method D-coded
- Current consumption typ. 30 mA ±15 % (at 24 V DC)
- Protocols supported SNMP v1
- Description of the input EN 61131-2 types 1 and 3
- Input filter time < 1000 µs
- Drill hole spacing 198.5 mm
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Designation connection point Copper cable
- Protective circuit Overload protection, short-circuit protection of outputs yes
- Output name Digital outputs
- Nominal output voltage 24 V DC (from voltage UA)
- Test section 24 V supply (communications power and sensor supply, digital inputs)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
- Output current when switched off max. 20 µA
- Depth 38 mm
- Permissible humidity (operation) 5 % ... 95 %
- Number 2
- Transmission speed 100 Mbps (with auto negotiation)
- Equipment type PROFINET-Device
- Number of inputs 8
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Output voltage 24 V DC
- Behavior with overload Auto restart
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Designation Actuators (UA)
- Number of positions 4
- Connection technology 3-conductor
- Input name Digital inputs
- Nominal input current at UIN typ. 3 mA
- Nominal load, inductive 12 VA (1.2 H, 48 Ω, with nominal voltage)
- UNSPSC 7.0901 43201404
- Height 185 mm
- Mounting type Wall mounting or DIN rail mounting; both with mounting plate.
- Net weight 739 g
- Width 60 mm
- Note on dimensions The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Nominal input voltage UIN 24 V DC
- Input voltage range "0" signal 0 V ... 5 V DC
- Switching frequency max. 5500 per second (with at least 50 mA load current)
- China RoHS Environmentally Friendly Use Period = 25;
- Conformance class B
- ECLASS 6.0 27242600
- ETIM 7.0 EC001599
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Housing material Zinc die-cast
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- System-specific protocols PROFINET protocols LLDP
- Connection method M12 connector, double occupancy
- Supply voltage 24 V DC
- REACh SVHC Lead 7439-92-1
- ECLASS 5.1 27242600
- ECLASS 9.0 27242604
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- UNSPSC 12.01 39121311
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- ETIM 2.0 EC001433
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- ECLASS 11.0 27242604
- ETIM 6.0 EC001599
- Number of outputs 8
- Reverse voltage resistance to short pulses Reverse voltage proof
- Output voltage when switched off max. 1 V
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 10.0.1 27242604
- UNSPSC 11 39121311
- UNSPSC 19.0 32151602
- Nominal load, ohmic 12 W (48 Ω, with nominal voltage)
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- ECLASS 5.0 27242200
- ETIM 3.0 EC001599
- UNSPSC 6.01 43172015
- UNSPSC 18.0 32151602
- ECLASS 4.1 27240400
- ECLASS 7.0 27242604
- UNSPSC 13.2 32151602
- ECLASS 4.0 27240400
- ETIM 4.0 EC001599
- UNSPSC 20.0 32151602
- UNSPSC 21.0 32151602
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?