2701513 Phoenix Contact Programmable Logic Controllers
Part#:2701513
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline E PROFINET device in a plastic housing with 8 IO-Link ports and 4 digital inputs, 24 V DC, M12 fast connection technology
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701513 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- ECLASS 4.1 27240400
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Note on dimensions The height is 212 mm including fixing clips.
- Protective circuit Overload protection, short-circuit protection of sensor supply
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Mounting type Wall mounting
- Designation connection point Copper cable
- Supply voltage 24 V DC
- Protocols supported SNMP v1
- Description of the input IO-Link ports in digital input (DI) mode
- Equipment type PROFINET-Device
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- UNSPSC 19.0 32151602
- Width 60 mm
- System-specific protocols PROFINET protocols LLDP
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Nominal input current at UIN typ. 3 mA
- Permissible humidity (operation) 5 % ... 95 %
- Color anthracite
- Note on the connection method D-coded
- Sensor current per channel max. 200 mA (from L+/L-)
- Nominal output voltage 24 V DC
- Designation Actuators (UA)
- Transmission speed 100 Mbps (with auto negotiation)
- Current consumption typ. 28 mA ±15 % (at 24 V DC)
- Number of inputs max. 8 (EN 61131-2 type 1)
- Input voltage range "0" signal -0.3 V DC ... 5 V DC
- Type of protection Overload protection
- Height 185 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Housing material Pocan®
- Number of outputs max. 8
- Maximum output current per device 1.2 A
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ETIM 3.0 EC001599
- Permissible humidity (storage/transport) 5 % ... 95 %
- Degree of protection IP65/IP67
- Connection method M12 connector, X01 ... X04 have double occupancy
- Number of positions 4
- Input name Digital inputs at pin 2 for type A ports
- Nominal input voltage UIN 24 V DC
- UNSPSC 21.0 32151602
- Depth 30.5 mm
- Input voltage range "1" signal 15 V DC ... 30 V DC
- Total sensor current max. 1.6 A (from L+/L-)
- Nominal load, ohmic 3.6 W (160 Ω, at nominal load)
- Conformance class B
- Number of supported application relationships (AR) 2
- Connection technology 3-conductor
- ECLASS 10.0.1 27242604
- ECLASS 4.0 27240400
- ETIM 2.0 EC001433
- Input filter time < 1000 µs
- Input frequency 0.5 kHz
- Drill hole spacing 198.5 mm
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Maximum output current per channel 150 mA
- Net weight 556.8 g
- Number 2
- Output current when switched off max. 300 µA
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- China RoHS Environmentally Friendly Use Period = 25;
- UNSPSC 6.01 43172015
- ETIM 6.0 EC001599
- Switching rate 1 per second, maximum (at nominal inductive load)
- Test section 24 V supply (communications power and sensor supply, IO-Link ports)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
- Output description IO-Link ports in digital output (DO) mode
- Nominal load, inductive 3.6 VA (0.8 H, 160 Ω, at nominal load)
- Limitation of the voltage induced on circuit interruption -15 V DC
- Output voltage when switched off max. 1 V
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Nominal input current typ. 3 mA
- Signal delay max. 150 µs (when switched on)
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 9.0 27242604
- UNSPSC 11 39121311
- UNSPSC 18.0 32151602
- ECLASS 6.0 27242600
- Behavior with overload Shutdown with automatic restart
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ETIM 7.0 EC001599
- UNSPSC 13.2 32151602
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- ECLASS 11.0 27242604
- ECLASS 5.1 27242600
- ETIM 4.0 EC001599
- ECLASS 7.0 27242604
- UNSPSC 7.0901 43201404
- UNSPSC 20.0 32151602
- ECLASS 5.0 27242200
- UNSPSC 12.01 39121311
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?