2701511 Phoenix Contact Programmable Logic Controllers
Part#:2701511
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline E, Digital I/O device, PROFINET, M12 fast connection technology, Digital inputs: 16, 24 V DC, connection method: 4-conductor, Digital outputs: 16, 24 V DC, 500 mA, connection method: 3-conductor, Plastic housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701511 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 60 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Housing material Pocan®
- Net weight 548.5 g
- Mounting type Wall mounting
- Equipment type PROFINET-Device
- Number of supported application relationships (AR) 2
- Current consumption typ. 3 mA ±15 % (at 24 V DC)
- Protective circuit Overload protection, short-circuit protection of outputs yes
- Cable length max. 30 m (To the sensor)
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Note on dimensions The height is 212 mm including fixing clips.
- Degree of protection IP65/IP67
- Designation Actuators (UA) for additional devices
- Transmission speed 100 Mbps (with auto negotiation)
- Conformance class B
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Nominal input voltage UIN 24 V DC
- ECLASS 4.1 27240400
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Height 185 mm
- Permissible humidity (operation) 5 % ... 95 %
- Permissible humidity (storage/transport) 5 % ... 95 %
- Connection method M12 connector, double occupancy
- Number of positions 4
- System-specific protocols PROFINET protocols LLDP
- Description of the input EN 61131-2 types 1 and 3
- Input name Digital inputs
- Nominal input current at UIN typ. 3 mA
- Output name Digital outputs
- Nominal output voltage 24 V DC (from voltage US)
- Output current when switched off max. 20 µA
- Protocols supported SNMP v1
- Connection technology 3-conductor
- Input voltage range "0" signal 0 V ... 5 V DC
- Output voltage 24 V DC
- Behavior with overload Auto restart
- Output voltage when switched off max. 1 V
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 10.0.1 27242604
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 5.1 27242600
- ETIM 6.0 EC001599
- UNSPSC 12.01 39121311
- Depth 30.5 mm
- Drill hole spacing 198.5 mm
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Color anthracite
- Note on the connection method D-coded
- Designation connection point Copper cable
- Number 2
- Supply voltage 24 V DC
- Number of inputs 16
- Number of outputs 16
- Input voltage range "1" signal 11 V DC ... 30 V DC
- ETIM 2.0 EC001433
- UNSPSC 7.0901 43201404
- UNSPSC 6.01 43172015
- UNSPSC 11 39121311
- Switching frequency max. 5500 per second (with at least 50 mA load current)
- UNSPSC 19.0 32151602
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- ECLASS 4.0 27240400
- ECLASS 11.0 27242604
- ECLASS 5.0 27242200
- Reverse voltage resistance to short pulses Reverse voltage proof
- ECLASS 6.0 27242600
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- ETIM 3.0 EC001599
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 9.0 27242604
- Input filter time < 1000 µs
- Nominal load, ohmic 12 W (48 Ω, with nominal voltage)
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- ECLASS 7.0 27242604
- UNSPSC 18.0 32151602
- Test section 24 V supply (communications power/sensor supply, digital inputs/outputs)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
- ETIM 7.0 EC001599
- UNSPSC 21.0 32151602
- Nominal load, inductive 12 VA (1.2 H, 48 Ω, with nominal voltage)
- China RoHS Environmentally Friendly Use Period = 25;
- ETIM 4.0 EC001599
- UNSPSC 13.2 32151602
- UNSPSC 20.0 32151602
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes