2701507 Phoenix Contact Programmable Logic Controllers
Part#:2701507
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline E, Digital I/O device, PROFIBUS DP, M12 fast connection technology, Digital inputs: 8, 24 V DC, connection method: 4-conductor, Digital outputs: 4, 24 V DC, 2 A, connection method: 3-conductor, Metal housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701507 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Number 2
- Designation connection point Copper cable
- Equipment type PROFIBUS slave
- Number of inputs 8
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Note on dimensions The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
- Nominal load, ohmic 48 W (48 Ω, with nominal voltage)
- Housing material Zinc die-cast
- Height 185 mm
- Nominal input voltage UIN 24 V DC
- Input filter time < 1000 µs
- Nominal output voltage 24 V DC (from voltage UA)
- Output voltage when switched off max. 1 V
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- REACh SVHC Lead 7439-92-1
- ECLASS 5.0 27242200
- ECLASS 7.0 27242604
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Connection method M12 connector, (A-coded)
- Designation Actuators (UA)
- Address area assignment 1 ... 126, adjustable
- System-specific protocols PROFIBUS protocols DP V1
- Input name Digital inputs
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- ECLASS 4.1 27240400
- ECLASS 10.0.1 27242604
- Ambient temperature (operation) -25 °C ... 60 °C
- Permissible humidity (storage/transport) 5 % ... 95 %
- Mounting type Wall mounting or DIN rail mounting; both with mounting plate.
- Note on the connection method B-coded
- Number of positions 4
- Supply voltage 24 V DC
- Nominal input current at UIN typ. 3 mA
- Output voltage 24 V DC
- Number of outputs 4
- Switching frequency max. 5500 per second (with at least 50 mA load current)
- Depth 38 mm
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 5.1 27242600
- ETIM 4.0 EC001599
- UNSPSC 12.01 39121311
- UNSPSC 19.0 32151602
- Current consumption typ. 30 mA ±15 % (at 24 V DC)
- Connection technology 3-conductor
- Description of the input EN 61131-2 types 1 and 3
- Output name Digital outputs
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 9.0 27242604
- ETIM 6.0 EC001599
- Width 60 mm
- Drill hole spacing 198.5 mm
- Permissible humidity (operation) 5 % ... 95 %
- Degree of protection IP65/IP67
- Net weight 726.3 g
- Transmission speed 9.6 kbps ... 12 Mbps (Automatic baud rate detection)
- Transmission physics PROFIBUS-DP-compliant copper cable
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Output current when switched off max. 20 µA
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- ECLASS 11.0 27242604
- ECLASS 4.0 27240400
- ECLASS 6.0 27242600
- ETIM 7.0 EC001599
- Protective circuit Overload protection, short-circuit protection of outputs yes
- Nominal load, inductive 48 VA (1.2 H, 48 Ω, with nominal voltage)
- Behavior with overload Auto restart
- Reverse voltage resistance to short pulses Reverse voltage proof
- Test section 24 V supply (communications power and sensor supply, digital inputs)/bus connection 500 V AC 50 Hz 1 min.
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ETIM 2.0 EC001433
- UNSPSC 13.2 32151602
- UNSPSC 20.0 32151602
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- UNSPSC 7.0901 43201404
- UNSPSC 21.0 32151602
- Input voltage range "0" signal 0 V ... 5 V DC
- UNSPSC 6.01 43172015
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- ETIM 3.0 EC001599
- UNSPSC 11 39121311
- UNSPSC 18.0 32151602
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?