Axioline E, Digital I/O device, PROFIBUS DP, M12 fast connection technology, Digital inputs: 16, 24 V DC, connection method: 4-conductor, Digital outputs: 16, 24 V DC, 500 mA, connection method: 3-conductor, Metal housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701506 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Note on dimensions The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Designation Actuators (UA) for additional devices
- Net weight 722.1 g
- Designation connection point Copper cable
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Nominal input voltage UIN 24 V DC
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Depth 38 mm
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Degree of protection IP65/IP67
- Number 2
- Equipment type PROFIBUS slave
- System-specific protocols PROFIBUS protocols DP V1
- Connection technology 3-conductor
- Nominal input current at UIN typ. 3 mA
- Output voltage 24 V DC
- Width 60 mm
- Drill hole spacing 198.5 mm
- Permissible humidity (storage/transport) 5 % ... 95 %
- Housing material Zinc die-cast
- Address area assignment 1 ... 126, adjustable
- Transmission physics PROFIBUS-DP-compliant copper cable
- Description of the input EN 61131-2 types 1 and 3
- Height 185 mm
- Permissible humidity (operation) 5 % ... 95 %
- Mounting type Wall mounting or DIN rail mounting; both with mounting plate.
- Note on the connection method B-coded
- Number of positions 4
- Current consumption typ. 3 mA ±15 % (at 24 V DC)
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (operation) -25 °C ... 60 °C
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Connection method M12 connector, double occupancy
- Transmission speed 9.6 kbps ... 12 Mbps (Automatic baud rate detection)
- Cable length max. 30 m (To the sensor)
- ECLASS 11.0 27242604
- ECLASS 9.0 27242604
- ETIM 4.0 EC001599
- ETIM 7.0 EC001599
- UNSPSC 20.0 32151602
- Number of inputs 16
- Input name Digital inputs
- Output name Digital outputs
- Number of outputs 16
- Output voltage when switched off max. 1 V
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 5.1 27242600
- ECLASS 7.0 27242604
- UNSPSC 11 39121311
- Supply voltage 24 V DC
- Behavior with overload Auto restart
- Test section 24 V supply (communications power and sensor supply, digital inputs/outputs)/bus connection 500 V AC 50 Hz 1 min.
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 4.0 27240400
- Input voltage range "0" signal 0 V ... 5 V DC
- Output current when switched off max. 20 µA
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 10.0.1 27242604
- ECLASS 6.0 27242600
- ETIM 6.0 EC001599
- UNSPSC 13.2 32151602
- UNSPSC 19.0 32151602
- Input filter time < 1000 µs
- Switching frequency max. 5500 per second (with at least 50 mA load current)
- Protective circuit Overload protection, short-circuit protection of outputs yes
- Nominal load, ohmic 12 W (48 Ω, with nominal voltage)
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Nominal output voltage 24 V DC (from voltage US)
- Nominal load, inductive 12 VA (1.2 H, 48 Ω, with nominal voltage)
- Reverse voltage resistance to short pulses Reverse voltage proof
- ECLASS 5.0 27242200
- ETIM 2.0 EC001433
- UNSPSC 6.01 43172015
- UNSPSC 7.0901 43201404
- UNSPSC 21.0 32151602
- ECLASS 4.1 27240400
- UNSPSC 18.0 32151602
- ETIM 3.0 EC001599
- REACh SVHC Lead 7439-92-1
- UNSPSC 12.01 39121311
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?