2701505 Phoenix Contact Programmable Logic Controllers
Part#:2701505
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline E, Digital input device, PROFIBUS DP, M12 fast connection technology, Digital inputs: 16, 24 V DC, connection method: 4-conductor, Metal housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701505 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Depth 38 mm
- Height 185 mm
- Permissible humidity (operation) 5 % ... 95 %
- Permissible humidity (storage/transport) 5 % ... 95 %
- Degree of protection IP65/IP67
- Note on the connection method B-coded
- Equipment type PROFIBUS slave
- Description of the input EN 61131-2 types 1 and 3
- Drill hole spacing 198.5 mm
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Transmission speed 9.6 kbps ... 12 Mbps (Automatic baud rate detection)
- Number of positions 4
- Current consumption typ. 3 mA ±15 % (at 24 V DC)
- UNSPSC 21.0 32151602
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Number 2
- Address area assignment 1 ... 126, adjustable
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Connection technology 4-conductor
- ECLASS 7.0 27242604
- Width 60 mm
- Note on dimensions The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
- ETIM 7.0 EC001599
- UNSPSC 20.0 32151602
- UNSPSC 18.0 32151602
- Housing material Zinc die-cast
- Transmission physics PROFIBUS-DP-compliant copper cable
- Input name Digital inputs
- System-specific protocols PROFIBUS protocols DP V1
- Supply voltage 24 V DC
- UNSPSC 19.0 32151602
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 6.0 27242600
- Protective circuit Overload protection, short-circuit protection of sensor supply
- Input filter time < 1000 µs
- Connection method M12 connector, double occupancy
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 5.1 27242600
- ETIM 4.0 EC001599
- ETIM 2.0 EC001433
- UNSPSC 7.0901 43201404
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Input voltage range "0" signal 0 V ... 5 V DC
- Test section 24 V supply (communications power and sensor supply, digital inputs)/bus connection 500 V AC 50 Hz 1 min.
- Designation Actuators (UA) for additional devices
- Designation connection point Copper cable
- Number of inputs 16
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27242604
- Net weight 707.8 g
- Nominal input current at UIN typ. 3 mA
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- ECLASS 9.0 27242604
- Ambient temperature (operation) -25 °C ... 60 °C
- Mounting type Wall mounting or DIN rail mounting; both with mounting plate.
- Nominal input voltage UIN 24 V DC
- ECLASS 4.1 27240400
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- UNSPSC 11 39121311
- UNSPSC 13.2 32151602
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 4.0 27240400
- ETIM 6.0 EC001599
- ECLASS 5.0 27242200
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- ETIM 3.0 EC001599
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- ECLASS 10.0.1 27242604
- UNSPSC 6.01 43172015
- UNSPSC 12.01 39121311
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?