Axioline E, Digital I/O device, PROFIBUS DP, M12 fast connection technology, Digital inputs: 8, 24 V DC, connection method: 4-conductor, Digital outputs: 8, 24 V DC, 500 mA, connection method: 3-conductor, Plastic housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701497 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Housing material Pocan®
- Depth 30.5 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Mounting type Wall mounting
- Number 2
- Height 185 mm
- Permissible humidity (operation) 5 % ... 95 %
- Color anthracite
- Protective circuit Overload protection, short-circuit protection of outputs yes
- Address area assignment 1 ... 126, adjustable
- Supply voltage 24 V DC
- Equipment type PROFIBUS slave
- Output voltage 24 V DC
- Output current when switched off max. 20 µA
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Degree of protection IP65/IP67
- Permissible humidity (storage/transport) 5 % ... 95 %
- Designation Actuators (UA)
- Transmission speed 9.6 kbps ... 12 Mbps (Automatic baud rate detection)
- Description of the input EN 61131-2 types 1 and 3
- Cable length max. 30 m (To the sensor)
- Nominal input current at UIN typ. 3 mA
- Input voltage range "0" signal 0 V ... 5 V DC
- Nominal load, ohmic 12 W (48 Ω, with nominal voltage)
- Note on dimensions The height is 212 mm including fixing clips.
- Nominal output voltage 24 V DC (from voltage UA)
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 11.0 27242604
- ETIM 6.0 EC001599
- UNSPSC 7.0901 43201404
- Width 60 mm
- Drill hole spacing 198.5 mm
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Connection method M12 connector, double occupancy
- Number of positions 4
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Nominal input voltage UIN 24 V DC
- Input filter time < 1000 µs
- Output name Digital outputs
- Output voltage when switched off max. 1 V
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- ECLASS 4.1 27240400
- ETIM 7.0 EC001599
- UNSPSC 18.0 32151602
- Net weight 552.5 g
- Note on the connection method B-coded
- Transmission physics PROFIBUS-DP-compliant copper cable
- System-specific protocols PROFIBUS protocols DP V1
- Input name Digital inputs
- Connection technology 3-conductor
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Nominal load, inductive 12 VA (1.2 H, 48 Ω, with nominal voltage)
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Test section 24 V supply (communications power and sensor supply, digital inputs)/bus connection 500 V AC 50 Hz 1 min.
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Behavior with overload Auto restart
- ECLASS 4.0 27240400
- ETIM 2.0 EC001433
- UNSPSC 11 39121311
- UNSPSC 21.0 32151602
- UNSPSC 13.2 32151602
- UNSPSC 19.0 32151602
- Designation connection point Copper cable
- Current consumption typ. 30 mA ±15 % (at 24 V DC)
- Number of inputs 8
- Number of outputs 8
- ECLASS 10.0.1 27242604
- ETIM 3.0 EC001599
- UNSPSC 20.0 32151602
- Switching frequency max. 5500 per second (with at least 50 mA load current)
- ECLASS 9.0 27242604
- ECLASS 5.0 27242200
- Reverse voltage resistance to short pulses Reverse voltage proof
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 5.1 27242600
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 6.0 27242600
- UNSPSC 12.01 39121311
- ETIM 4.0 EC001599
- ECLASS 7.0 27242604
- UNSPSC 6.01 43172015
- REACh SVHC Lead 7439-92-1
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.