Axioline E, Digital I/O device, EtherNet/IP™, M12 fast connection technology, Digital inputs: 16, 24 V DC, connection method: 4-conductor, Digital outputs: 16, 24 V DC, 500 mA, connection method: 3-conductor, Metal housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701489 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Number 2
- Equipment type EtherNet/IP™ slave
- System-specific protocols EtherNet/IP™ protocols ACD
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Drill hole spacing 198.5 mm
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000Â m above sea level)
- Specification CIP Edition 3.11EIP adaptation of CIP 1.12
- Current consumption typ. 3 mA ±15 % (at 24 V DC)
- ECLASS 7.0 27242604
- Supply voltage range 18 VÂ DC ... 31.2 VÂ DC (including all tolerances, including ripple)
- ECLASS 5.0 27242200
- UNSPSC 21.0 32151602
- UNSPSC 18.0 32151602
- Height 185 mm
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Mounting type Wall mounting or DIN rail mounting; both with mounting plate.
- Designation connection point Copper cable
- Connection method M12 connector, double occupancy
- Width 60 mm
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000Â m above sea level)
- Permissible humidity (storage/transport) 5 % ... 95 %
- Net weight 713.8 g
- Designation Actuators (UA) for additional devices
- Number of positions 4
- Input name Digital inputs
- Nominal input voltage UIN 24 VÂ DC
- Protective circuit Overload protection, short-circuit protection of outputs yes
- ECLASS 9.0 27242604
- UNSPSC 12.01 39121311
- UNSPSC 20.0 32151602
- Note on dimensions The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
- Permissible humidity (operation) 5 % ... 95 %
- Housing material Zinc die-cast
- Transmission speed 10/100 Mbps (with auto negotiation)
- Supply voltage 24 VÂ DC
- ETIM 2.0 EC001433
- ETIM 4.0 EC001599
- UNSPSC 11 39121311
- UNSPSC 19.0 32151602
- ECLASS 11.0 27242604
- Depth 38 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Degree of protection IP65/IP67
- UNSPSC 13.2 32151602
- Note on the connection method D-coded
- Protocols supported SNMP v1
- Connection technology 3-conductor
- Input voltage range "0" signal 0 V ... 5 VÂ DC
- Nominal output voltage 24 VÂ DC (from voltage US)
- Test section 24 V supply (communications power/sensor supply, digital inputs/outputs)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
- Reverse voltage resistance to short pulses Reverse voltage proof
- REACh SVHC Lead 7439-92-1
- Input filter time < 1000 µs
- Cable length max. 30 m (To the sensor)
- Nominal load, inductive 12 VA (1.2 H, 48 Ω, with nominal voltage)
- Nominal load, ohmic 12 W (48 Ω, with nominal voltage)
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields ENÂ 61000-4-3/IECÂ 61000-4-3 Criterion A, Field intensity: 10 V/m
- ECLASS 10.0.1 27242604
- Output voltage 24 VÂ DC
- Output voltage when switched off max. 1 V
- Behavior with overload Auto restart
- Description of the input EN 61131-2 types 1 and 3
- Input voltage range "1" signal 11 VÂ DC ... 30 VÂ DC
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- Output name Digital outputs
- Number of inputs 16
- Nominal input current at UIN typ. 3 mA
- Number of outputs 16
- Output current when switched off max. 20 µA
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference ENÂ 61000-4-6/IECÂ 61000-4-6 Criterion A, Test voltage 10 V
- Mechanical tests Vibration resistance in acc. with ENÂ 60068-2-6/IECÂ 60068-2-6 5g
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- UNSPSC 6.01 43172015
- ECLASS 4.1 27240400
- ETIM 7.0 EC001599
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 6.0 27242600
- ETIM 6.0 EC001599
- Switching frequency max. 5500 per second (with at least 50Â mA load current)
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) ENÂ 61000-4-2/IECÂ 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) ENÂ 61000-4-4/IECÂ 61000-4-4 Criterion B, 2Â kV
- Protection class III (IECÂ 61140, ENÂ 61140, VDEÂ 0140-1)
- ECLASS 5.1 27242600
- ETIM 3.0 EC001599
- ECLASS 4.0 27240400
- UNSPSC 7.0901 43201404
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?