2701488 Phoenix Contact Programmable Logic Controllers
Part#:2701488
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline E, Digital input device, EtherNet/IP™, M12 fast connection technology, Digital inputs: 16, 24 V DC, connection method: 4-conductor, Metal housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701488 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 185 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Permissible humidity (storage/transport) 5 % ... 95 %
- Designation Actuators (UA) for additional devices
- Specification CIP Edition 3.11EIP adaptation of CIP 1.12
- Current consumption typ. 3 mA ±15 % (at 24 V DC)
- Nominal input current at UIN typ. 3 mA
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- REACh SVHC Lead 7439-92-1
- Width 60 mm
- Permissible humidity (operation) 5 % ... 95 %
- Number 2
- Housing material Zinc die-cast
- Number of positions 4
- Supply voltage 24 V DC
- Cable length max. 30 m (To the sensor)
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Description of the input EN 61131-2 types 1 and 3
- ECLASS 4.0 27240400
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Note on dimensions The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
- Mounting type Wall mounting or DIN rail mounting; both with mounting plate.
- Note on the connection method D-coded
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Net weight 714.4 g
- Transmission speed 10/100 Mbps (with auto negotiation)
- System-specific protocols EtherNet/IP™ protocols ACD
- Number of inputs 16
- Nominal input voltage UIN 24 V DC
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Drill hole spacing 198.5 mm
- Test section 24 V supply (communications power and sensor supply, digital inputs)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
- Degree of protection IP65/IP67
- Protective circuit Overload protection, short-circuit protection of sensor supply
- Input filter time < 1000 µs
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 10.0.1 27242604
- ECLASS 11.0 27242604
- ETIM 7.0 EC001599
- UNSPSC 7.0901 43201404
- ECLASS 5.1 27242600
- UNSPSC 11 39121311
- ECLASS 6.0 27242600
- ECLASS 7.0 27242604
- UNSPSC 21.0 32151602
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Designation connection point Copper cable
- Protocols supported SNMP v1
- Connection method M12 connector, double occupancy
- Depth 38 mm
- Input name Digital inputs
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 5.0 27242200
- ECLASS 9.0 27242604
- ETIM 3.0 EC001599
- ETIM 2.0 EC001433
- UNSPSC 12.01 39121311
- Equipment type EtherNet/IP™ slave
- Input voltage range "0" signal 0 V ... 5 V DC
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 4.1 27240400
- ETIM 6.0 EC001599
- ETIM 4.0 EC001599
- UNSPSC 19.0 32151602
- UNSPSC 20.0 32151602
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Connection technology 4-conductor
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- China RoHS Environmentally Friendly Use Period = 25;
- UNSPSC 6.01 43172015
- UNSPSC 13.2 32151602
- UNSPSC 18.0 32151602
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?