Axioline E, Digital I/O device, EtherNet/IP™, M12 fast connection technology, Digital inputs: 8, 24 V DC, connection method: 4-conductor, Digital outputs: 8, 24 V DC, 500 mA, connection method: 3-conductor, Metal housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701487 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 185 mm
- Permissible humidity (operation) 5 % ... 95 %
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Net weight 709.1 g
- Input filter time < 1000 µs
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Number of positions 4
- System-specific protocols EtherNet/IP™ protocols ACD
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Current consumption typ. 30 mA ±15 % (at 24 V DC)
- Input name Digital inputs
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- Nominal input voltage UIN 24 V DC
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Drill hole spacing 198.5 mm
- Housing material Zinc die-cast
- Connection method M12 connector, double occupancy
- Transmission speed 10/100 Mbps (with auto negotiation)
- Protective circuit Overload protection, short-circuit protection of outputs yes
- Output voltage 24 V DC
- Nominal load, ohmic 12 W (48 Ω, with nominal voltage)
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- ECLASS 11.0 27242604
- ECLASS 6.0 27242600
- ETIM 3.0 EC001599
- ETIM 4.0 EC001599
- UNSPSC 11 39121311
- Degree of protection IP65/IP67
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- ECLASS 10.0.1 27242604
- REACh SVHC Lead 7439-92-1
- ECLASS 9.0 27242604
- UNSPSC 6.01 43172015
- UNSPSC 19.0 32151602
- UNSPSC 21.0 32151602
- Equipment type EtherNet/IP™ slave
- Specification CIP Edition 3.11EIP adaptation of CIP 1.12
- Description of the input EN 61131-2 types 1 and 3
- Nominal input current at UIN typ. 3 mA
- Nominal output voltage 24 V DC (from voltage UA)
- Output current when switched off max. 20 µA
- Input voltage range "0" signal 0 V ... 5 V DC
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- Width 60 mm
- Note on dimensions The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
- Permissible humidity (storage/transport) 5 % ... 95 %
- Mounting type Wall mounting or DIN rail mounting; both with mounting plate.
- Number 2
- Designation connection point Copper cable
- Supply voltage 24 V DC
- Number of inputs 8
- Output name Digital outputs
- Nominal load, inductive 12 VA (1.2 H, 48 Ω, with nominal voltage)
- Reverse voltage resistance to short pulses Reverse voltage proof
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 5.0 27242200
- ETIM 7.0 EC001599
- UNSPSC 12.01 39121311
- Depth 38 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Designation Actuators (UA)
- Note on the connection method D-coded
- Protocols supported SNMP v1
- Connection technology 3-conductor
- Cable length max. 30 m (To the sensor)
- Number of outputs 8
- Switching frequency max. 5500 per second (with at least 50 mA load current)
- Output voltage when switched off max. 1 V
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 4.0 27240400
- ECLASS 5.1 27242600
- ECLASS 7.0 27242604
- ETIM 6.0 EC001599
- UNSPSC 13.2 32151602
- Behavior with overload Auto restart
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- ECLASS 4.1 27240400
- ETIM 2.0 EC001433
- UNSPSC 20.0 32151602
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- UNSPSC 18.0 32151602
- UNSPSC 7.0901 43201404
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?