Axiocontrol for the direct control of Axioline I/Os. With 2 Ethernet interfaces, extended temperature range, and programming options according to IEC 61131-3. Complete with connector connector and marking field.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701295 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight 195 g
- Air pressure (storage/transport) 58 kPa ... 106 kPa (up to 4500 m above mean sea level)
- Shock 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
- Program memory 2 Mbyte
- Number of control tasks 8
- Number of local bus devices that can be connected max. 63 (observe current consumption)
- Specification Version 2.3
- Width 45 mm
- Configuration tool Config+ Version 1.01 or later
- Accuracy realtime clock 1.73 s/day = 20 ppm at 25 °C
- Interface Service
- Number 1
- Max. current consumption 160 mA
- Safety function No
- Number of supported devices max. 63 (per station)
- Device function PROFINET controller, PROFINET device
- Supply voltage range 19.2 V DC ... 30 V DC
- Power dissipation max. 3 W
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- ECLASS 10.0.1 27242207
- UNSPSC 19.0 39122114
- Vibration (operation) 5g
- Retentive mass storage 48 kByte (NVRAM)
- Diagnostics tool DIAG+
- Amount of process data max. 8192 Bit (per station)
- Transmission speed max. 115.2 kbps
- Realtime clock Yes
- Residual ripple ± 5 %
- Note on weight specifications with connector and bus base module
- Diagnostics display No
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Vibration (storage/transport) 5g
- Depth 74 mm
- Engineering tool PC WORX
- Programming languages supported Programming in acc. with IEC 61131-3
- Mass storage 2 Mbyte
- Connection method Micro USB type B
- Typical current consumption 125 mA
- Supply voltage 24 V DC
- Processor Altera Nios II 1x 100 MHz
- Shock (operation) 10g (Bump endurance test according to DIN EN 60068-2-27)
- UNSPSC 21.0 39122114
- Controller redundancy No
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 4.0 27240600
- ECLASS 5.1 27242700
- ECLASS 7.0 27242207
- UNSPSC 6.01 81111810
- Update rate min. 32 ms (16 devices)
- UNSPSC 13.2 39122114
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Ambient temperature (operation) -40 °C ... 70 °C up to 2000 m above mean sea level (observe derating)
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Degree of protection IP20
- Permissible humidity (operation) 5 % ... 95 % (according to DIN EN 61131-2, non-condensing, no ice formation)
- Height 126.1 mm
- Permissible humidity (storage/transport) 5 % ... 95 % (according to DIN EN 61131-2, non-condensing, no ice formation)
- China RoHS Environmentally Friendly Use Period = 50 years
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27240600
- ETIM 3.0 EC001045
- ETIM 7.0 EC000236
- UNSPSC 18.0 39122114
- ETIM 6.0 EC000236
- UNSPSC 12.01 81111810
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- ECLASS 5.0 27242700
- ETIM 4.0 EC001435
- UNSPSC 7.0901 81111810
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
- ECLASS 11.0 27242207
- ECLASS 6.0 27242200
- ECLASS 9.0 27242207
- UNSPSC 11 81111810
- UNSPSC 20.0 39122114
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?