Axioline F XC, Function module, Counter input for 24 V signals: 2, Incremental encoder inputs: 2, Symmetrical and asymmetrical encoders, Digital inputs: 8, 24 V DC, Digital outputs: 2, 24 V DC, Extreme conditions version, transmission speed in the local b

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2701239 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Caption
    Dimensional drawing
  • Height
    126.1 mm
  • Ambient temperature (operation)
    -25 °C ... 60 °C (Standard, applications with UL approval, use in zone 2 potentially explosive area)
  • Note on dimensions
    The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
  • Description of the input
    EN 61131-2, type 3
  • Encoder signals
    Symmetrical and asymmetrical encoders
  • Input current
    2.5 mA (per channel)
  • Nominal output voltage
    24 V DC
  • Current carrying capacity
    typ. 500 mA
  • Type of connection of signals
    Push-in connection
  • Connection technology
    1-conductor
  • Nominal input current at UIN
    2.5 mA (per channel)
  • Nominal load, lamp
    max. 12 W (at nominal voltage)
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Width
    53.6 mm
  • Depth
    54 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • ECLASS 5.1
    27242600
  • UNSPSC 6.01
    43172015
  • UNSPSC 18.0
    32151602
  • ETIM 7.0
    EC001601
  • UNSPSC 19.0
    32151602
  • Overvoltage category
    II (IEC 60664-1, EN 60664-1)
  • ECLASS 4.1
    27240400
  • ECLASS 9.0
    27242605
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Net weight
    233.9 g
  • Mounting type
    DIN rail
  • Degree of pollution
    2 (IEC 60664-1, EN 60664-1)
  • Connection method
    Push-in connection
  • Designation
    Asymmetrical incremental encoder
  • Supply voltage
    24 V DC
  • UNSPSC 13.2
    32151602
  • Type of protection
    Short-circuit protection
  • UNSPSC 21.0
    32151602
  • Input voltage range "0" signal
    -3 V DC ... 5 V DC
  • Input frequency
    max. 300 kHz (1 channel wired)
  • Cable length
    < 30 m
  • Permissible cable length to the sensor
    < 30 m
  • Interference emission
    Noise emission test according to EN 61000-6-3 Class B
  • ECLASS 4.0
    27240400
  • UNSPSC 20.0
    32151602
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • Input name
    Digital inputs
  • Supply voltage range
    19.2 V DC ... 30 V DC including all tolerances, including ripple
  • Number of 5 V encoder supplies
    2 (UE1, UE2)
  • Voltage range
    19.2 V DC ... 30 V DC
  • Common mode voltage range signal - ground
    -10 V ... 13.2 V
  • ECLASS 11.0
    27242605
  • ECLASS 5.0
    27242200
  • ETIM 3.0
    EC001599
  • ETIM 4.0
    EC001435
  • Degree of protection
    IP20
  • Mounting position
    any (no temperature derating)
  • Current consumption
    max. 2.5 A (dependent on the encoder or sensor type used and the load on the digital output.)
  • Protection
    max. 8 A (polarity reversal protection up to 5 A)
  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)
  • ECLASS 7.0
    27242605
  • UNSPSC 12.01
    39121311
  • Transmission speed
    100 Mbps
  • Power consumption
    max. 60 W (of which 1.6 W internal losses)
  • Resolution
    32 bits
  • Nominal load, inductive
    max. 12 VA (1.2 H, 48 Ω, with nominal voltage)
  • REACh SVHC
    Lead 7439-92-1
  • UL, USA/Canada
    cULus
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ETIM 6.0
    EC001601
  • UNSPSC 7.0901
    43201404
  • Number of inputs
    8 (CNT: G1, G2, Dir1, Dir2; INC: Ref1, Ref2, L1, L2)
  • IECEx
    Ex ec IIC T4 Gc
  • ECLASS 10.0.1
    27242605
  • ECLASS 6.0
    27242600
  • Color
    traffic grey A RAL 7042
  • Note on weight specifications
    with connectors and bus base module
  • Number of interfaces
    2
  • Protective circuit
    Short-circuit protection
  • UNSPSC 11
    39121311
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • Input voltage range "1" signal
    11 V DC ... 30 V DC
  • Encoder types that can be connected
    max. 2 (A, B, (Z))
  • Signal voltage level
    Low ≤ 2.5 V, high ≥ 3.5 V (up to 27 V, maximum)
  • Output voltage
    24 V DC
  • Input voltage
    24 V DC
  • Number of 24 V encoder supplies
    2 (US1, US2)
  • Number of outputs
    2 (Out1, Out2)
  • Nominal load, ohmic
    max. 12 W (48 Ω, with nominal voltage)
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • Nominal input voltage UIN
    24 V DC
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • ATEX
     II 3 G Ex ec IIC T4 Gc
  • Encoder supply voltage
    5 V DC
  • Output name
    Digital outputs

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?