Axioline F XC, Analog output module, Analog outputs: 8, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2-conductor, transmission speed in the local bus: 100 Mbps, Extreme condi

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2701237 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Height
    126.1 mm
  • Degree of protection
    IP20
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Note on weight specifications
    with connectors and bus base module
  • Number of interfaces
    2
  • Number of outputs
    8
  • Mounting position
    any (no temperature derating)
  • Supply voltage range
    19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • Current consumption
    typ. 110 mA (8 voltage channels, 10 V output)
  • Depth
    54 mm
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Mounting type
    DIN rail
  • Note on dimensions
    The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Net weight
    260 g
  • Connection method
    Push-in connection
  • Power consumption
    typ. 1.725 W (to UBus and UA; power input; no load, output 0 V)
  • Output name
    Analog outputs
  • Data formats
    IB IL, S7-compatible
  • Current output signal
    0 mA ... 20 mA
  • Permissible cable length
    max. 250 m (Reference cable type LiYCY (TP) n*2*0.5 mm²)
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
  • ECLASS 6.0
    27242600
  • ETIM 7.0
    EC001596
  • UNSPSC 7.0901
    43201404
  • UNSPSC 18.0
    32151602
  • UNSPSC 20.0
    32151602
  • Width
    53.6 mm
  • Ambient temperature (operation)
    -25 °C ... 60 °C (Standard)
  • Color
    traffic grey A RAL 7042
  • Designation
    Supply for analog modules (UA)
  • Supply voltage
    24 V DC
  • Note regarding the connection technology
    shielded, twisted pair
  • Type of protection
    Short-circuit and overload protection
  • Test section
    5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.0
    27242200
  • ETIM 3.0
    EC001599
  • ETIM 6.0
    EC001596
  • UNSPSC 13.2
    32151602
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Representation of output values
    16 bits (15 bits + sign)
  • Protective circuit
    Surge protection electronic (35 V, 0.5 s)
  • Process data update
    300 µs
  • Voltage output signal
    0 V ... 5 V
  • Precision
    typ. 0.1 % (of output range final value)
  • Interference emission
    Noise emission test according to EN 61000-6-3 Class B
  • ECLASS 10.0.1
    27242601
  • ECLASS 4.1
    27240400
  • UNSPSC 11
    39121311
  • UNSPSC 19.0
    32151602
  • Transmission speed
    100 Mbps
  • D/A conversion time
    5 µs
  • ECLASS 7.0
    27242601
  • ETIM 4.0
    EC001435
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 up to HW 01: Criterion B,DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27242600
  • ECLASS 9.0
    27242601
  • UNSPSC 6.01
    43172015
  • UNSPSC 12.01
    39121311
  • UNSPSC 21.0
    32151602
  • Protective circuit/component
    electronic
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • ECLASS 4.0
    27240400
  • Load/output load voltage output
    > 2 kΩ
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • Degree of pollution
    2 (IEC 60664-1, EN 60664-1)
  • Load/output load current output
    to 500 Ω
  • Connection technology
    2-conductor
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • D/A converter resolution
    16 bit
  • ECLASS 11.0
    27242601
  • Overvoltage category
    II (IEC 60664-1, EN 60664-1)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?