Inline XC, Temperature measurement terminal, Analog UTH inputs: 2 (Thermocouples or linear voltage), connection method: 2-conductor, transmission speed in the local bus: 500 kbps, Extreme conditions version, degree of protection: IP20, including Inline co
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701216 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth 71.5 mm
- Degree of protection IP20
- Net weight 105 g
- UNSPSC 7.0901 43201404
- ETIM 7.0 EC001596
- UNSPSC 21.0 32151602
- Height 136.8 mm
- Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
- ETIM 6.0 EC001596
- UNSPSC 13.2 32151602
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- UNSPSC 12.01 43201404
- UNSPSC 20.0 32151602
- Width 12.2 mm
- Note on dimensions Housing dimensions
- Note on weight specifications with connector
- ECLASS 9.0 27242601
- UNSPSC 6.01 43172015
- UNSPSC 19.0 32151602
- Ambient temperature (operation) -25 °C ... 55 °C (Standard)
- Permissible humidity (operation) 10 % ... 95 % (non-condensing)
- Color green
- UNSPSC 11 43172015
- UNSPSC 18.0 32151602
- Transmission speed 500 kbps
- Input name Analog UTH inputs
- A/D conversion time typ. 120 µs (per channel)
- Connection in acc. with standard CUL
- ECLASS 7.0 27242601
- ECLASS 5.0 27250300
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Operating mode Process data operation with 2 words
- Number 2
- Current consumption typ. 11 mA
- Note regarding the connection technology Shielded compensating line for TC with encapsulated sensors
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Connection method Inline connector
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Description of the input Inputs for thermocouples or linear voltage
- Sensor types that can be used (TC) U, T, L, J, E, K, N, S, R, B, C, W, HK
- ECLASS 10.0.1 27242601
- Type of protection Surge protection (TC channels)
- ECLASS 5.1 27242600
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Designation Supply of analog modules (UANA)
- Power consumption typ. 587 mW
- Number of inputs 2 (Thermocouples or linear voltage)
- Measuring principle Successive approximation
- Test section 7.5 V supply (bus logics)/24 V analog supply (analog I/O) 500 V AC 50 Hz 1 min.
- ECLASS 11.0 27242601
- ECLASS 6.0 27242600
- Mounting type DIN rail
- Diagnostics messages Failure of the internal I/O supply I/O error message sent to the bus coupler
- Supply voltage 24 V DC (via voltage jumper)
- Connection technology 2-conductor
- Measured value representation 16 bits (15 bits + sign bit)
- Process data update max. 30 ms (For both channels)
- ECLASS 4.1 27250300
- ETIM 3.0 EC001596
- ETIM 4.0 EC001599
- ECLASS 4.0 27250300
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?