2701034 Phoenix Contact Programmable Logic Controllers
Part#:2701034
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Inline controller for use under harsh ambient conditions, with Ethernet interface for coupling to other controllers and systems, with programming options according to IEC 61131-3, complete with connector and labeling field.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701034 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight 285 g
- Programming languages supported Programming in acc. with IEC 61131-3
- Realtime clock Yes
- Interface Parameterization/operation/diagnostics
- Number of inputs 8
- ETIM 4.0 EC000236
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Ambient temperature (operation) -40 °C ... 60 °C
- Vibration (operation) 5g
- Mass storage 192 kByte
- Retentive mass storage 8 kByte (NVRAM)
- Number of supported devices max. 63
- Connection method Spring-cage connection
- Depth 71.5 mm
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Configuration tool Config+ Version 1.01 or later
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- ECLASS 10.0.1 27242207
- Processor Altera Nios II 64 MHz
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Number of local bus devices that can be connected max. 63 (observe current consumption)
- Connection technology 2-, 3-, 4-conductor
- Residual ripple ± 5 %
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV
- Number 1
- Device function PROFINET device
- Maximum output current per channel 500 mA
- Supply voltage range 19.2 V DC ... 30 V DC
- Controller redundancy No
- Diagnostics display No
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27240600
- ECLASS 6.0 27242200
- Power dissipation max. 5 W
- Supply voltage 24 V DC
- Safety function No
- ECLASS 5.0 27242700
- ECLASS 11.0 27242207
- ECLASS 9.0 27242207
- Number of outputs 4
- Max. current consumption 870 mA (370 mA communications power + 500 mA analog voltage supply)
- Input name Digital inputs
- Description of the input EN 61131-2 type 1 NPN/PNP
- Typical current consumption 210 mA
- Interference emission Noise emission test as per EN 61000-6-4 EN 55011 Class A
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 5.1 27242700
- Number of devices with parameter channel max. 8
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- China RoHS Environmentally Friendly Use Period = 50 years
- ETIM 3.0 EC000236
- ECLASS 4.0 27250200
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical), fieldbus cable shield 1 kV
- UNSPSC 6.01 43172015
- Amount of process data max. 4096 Bit (INTERBUS)
- Vibration (storage/transport) 5g
- ECLASS 7.0 27242207
- UNSPSC 21.0 39122114
- Shock 25g, Criterion 1, according to IEC 60068-2-27
- Degree of protection IP20
- Diagnostics tool DIAG+
- UNSPSC 7.0901 43201404
- UNSPSC 12.01 43201404
- UNSPSC 11 43172018
- UNSPSC 19.0 39122114
- Height 119.8 mm
- Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2)
- Engineering tool PC WORX
- Battery not integrated (no buffering)
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- ETIM 6.0 EC000236
- Number of control tasks 8
- UNSPSC 13.2 39122114
- UNSPSC 20.0 39122114
- Width 80 mm
- Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2)
- Program memory 192 kByte
- Transmission speed max. 115.2 kbps
- Output name Digital outputs
- ETIM 7.0 EC000236
- UNSPSC 18.0 39122114
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?