2700976 Phoenix Contact Programmable Logic Controllers

2700976 on Power Resource International
Phoenix Contact

Part#:2700976

Manufacturer:Phoenix Contact

Category:Programmable Logic Controllers

Product Lifecycle:Active

Get a quick Quote!

The Inline controller offers the option of communicating via PROFINET and Modbus/TCP. Programming is carried out using PC Worx Express or PC Worx (IEC 61131-3).

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2700976 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Weight
    285 g
  • Height
    119.8 mm
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Engineering tool
    PC WORX
  • Retentive mass storage
    48 kByte (NVRAM)
  • Number of supported branch terminals with remote bus branch
    max. 3
  • Number of inputs
    8
  • Maximum output current per channel
    500 mA
  • Controller redundancy
    No
  • Configuration tool
    Config+ Version 1.01 or later
  • Mass storage
    1 Mbyte
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • ECLASS 5.0
    27242700
  • ECLASS 7.0
    27242207
  • ECLASS 9.0
    27242207
  • UNSPSC 7.0901
    43201404
  • Number of local bus devices that can be connected
    max. 63 (observe current consumption)
  • Transmission speed
    max. 115.2 kbps
  • Depth
    71.5 mm
  • Ambient temperature (storage/transport)
    -25 °C ... 85 °C
  • Shock
    25g, Criterion 1, according to IEC 60068-2-27
  • Connection technology
    2-, 3-, 4-conductor
  • Supply voltage range
    19.2 V DC ... 30 V DC
  • Power dissipation
    max. 5 W
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Realtime clock
    Yes
  • UNSPSC 18.0
    39122114
  • UNSPSC 21.0
    39122114
  • Number of devices with parameter channel
    max. 24
  • Connection method
    Spring-cage connection
  • Number of outputs
    4
  • Residual ripple
    ± 5 %
  • Diagnostics display
    No
  • REACh SVHC
    1,2-dimethoxyethane,ethylene glycol dimethyl ether (EGDME) 110-71-4
  • ECLASS 6.0
    27242200
  • ETIM 7.0
    EC000236
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Program memory
    1 Mbyte
  • Battery
    Integrated (rechargeable battery buffered)
  • Number
    1
  • Typical current consumption
    210 mA
  • Processor
    Altera Nios II 64 MHz
  • ECLASS 4.0
    27250200
  • Safety function
    No
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV
  • UNSPSC 11
    43172018
  • ECLASS 4.1
    27240600
  • ETIM 3.0
    EC000236
  • UNSPSC 13.2
    39122114
  • Ambient temperature (operation)
    -25 °C ... 55 °C
  • Permissible humidity (operation)
    10 % ... 95 % (according to DIN EN 61131-2)
  • Vibration (operation)
    5g
  • Amount of process data
    max. 4096 Bit (INTERBUS)
  • Supply voltage
    24 V DC
  • Degree of protection
    IP20
  • Diagnostics tool
    DIAG+
  • Number of control tasks
    8
  • Input name
    Digital inputs
  • Max. current consumption
    870 mA (370 mA communications power + 500 mA analog voltage supply)
  • ECLASS 5.1
    27242700
  • Number of supported devices
    max. 128
  • Clock frequency
    64 MHz
  • Interface
    Parameterization/operation/diagnostics
  • Interference emission
    Noise emission test as per EN 61000-6-4 EN 55011 Class A
  • Vibration (storage/transport)
    5g
  • ECLASS 10.0.1
    27242207
  • ETIM 4.0
    EC000236
  • UNSPSC 12.01
    43201404
  • UNSPSC 19.0
    39122114
  • Width
    80 mm
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 11.0
    27242207
  • ETIM 6.0
    EC000236
  • UNSPSC 6.01
    43172015
  • UNSPSC 20.0
    39122114
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • Description of the input
    EN 61131-2 type 1 NPN/PNP
  • Device function
    PROFINET device
  • Permissible humidity (storage/transport)
    10 % ... 95 % (according to DIN EN 61131-2)
  • Output name
    Digital outputs
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical), fieldbus cable shield 1 kV
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • Programming languages supported
    Programming in acc. with IEC 61131-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?