2700976 Phoenix Contact Programmable Logic Controllers
Part#:2700976
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
The Inline controller offers the option of communicating via PROFINET and Modbus/TCP. Programming is carried out using PC Worx Express or PC Worx (IEC 61131-3).
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2700976 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight 285 g
- Height 119.8 mm
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Engineering tool PC WORX
- Retentive mass storage 48 kByte (NVRAM)
- Number of supported branch terminals with remote bus branch max. 3
- Number of inputs 8
- Maximum output current per channel 500 mA
- Controller redundancy No
- Configuration tool Config+ Version 1.01 or later
- Mass storage 1 Mbyte
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- ECLASS 5.0 27242700
- ECLASS 7.0 27242207
- ECLASS 9.0 27242207
- UNSPSC 7.0901 43201404
- Number of local bus devices that can be connected max. 63 (observe current consumption)
- Transmission speed max. 115.2 kbps
- Depth 71.5 mm
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Shock 25g, Criterion 1, according to IEC 60068-2-27
- Connection technology 2-, 3-, 4-conductor
- Supply voltage range 19.2 V DC ... 30 V DC
- Power dissipation max. 5 W
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Realtime clock Yes
- UNSPSC 18.0 39122114
- UNSPSC 21.0 39122114
- Number of devices with parameter channel max. 24
- Connection method Spring-cage connection
- Number of outputs 4
- Residual ripple ± 5 %
- Diagnostics display No
- REACh SVHC 1,2-dimethoxyethane,ethylene glycol dimethyl ether (EGDME) 110-71-4
- ECLASS 6.0 27242200
- ETIM 7.0 EC000236
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Program memory 1 Mbyte
- Battery Integrated (rechargeable battery buffered)
- Number 1
- Typical current consumption 210 mA
- Processor Altera Nios II 64 MHz
- ECLASS 4.0 27250200
- Safety function No
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV
- UNSPSC 11 43172018
- ECLASS 4.1 27240600
- ETIM 3.0 EC000236
- UNSPSC 13.2 39122114
- Ambient temperature (operation) -25 °C ... 55 °C
- Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2)
- Vibration (operation) 5g
- Amount of process data max. 4096 Bit (INTERBUS)
- Supply voltage 24 V DC
- Degree of protection IP20
- Diagnostics tool DIAG+
- Number of control tasks 8
- Input name Digital inputs
- Max. current consumption 870 mA (370 mA communications power + 500 mA analog voltage supply)
- ECLASS 5.1 27242700
- Number of supported devices max. 128
- Clock frequency 64 MHz
- Interface Parameterization/operation/diagnostics
- Interference emission Noise emission test as per EN 61000-6-4 EN 55011 Class A
- Vibration (storage/transport) 5g
- ECLASS 10.0.1 27242207
- ETIM 4.0 EC000236
- UNSPSC 12.01 43201404
- UNSPSC 19.0 39122114
- Width 80 mm
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 11.0 27242207
- ETIM 6.0 EC000236
- UNSPSC 6.01 43172015
- UNSPSC 20.0 39122114
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Description of the input EN 61131-2 type 1 NPN/PNP
- Device function PROFINET device
- Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2)
- Output name Digital outputs
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical), fieldbus cable shield 1 kV
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Programming languages supported Programming in acc. with IEC 61131-3
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?