2700975 Phoenix Contact Programmable Logic Controllers
Part#:2700975
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
The Inline controller offers the option of communicating via PROFINET and Modbus/TCP. Programming is carried out using PC Worx Express or PC Worx (IEC 61131-3).
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2700975 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight 295 g
- Interface Parameterization/operation/diagnostics
- Vibration (storage/transport) 5g
- UNSPSC 13.2 39122114
- Number of supported branch terminals with remote bus branch max. 3
- ECLASS 6.0 27242200
- Height 119.8 mm
- Degree of protection IP20
- Diagnostics tool DIAG+
- Amount of process data max. 4096 Bit (INTERBUS)
- Number 1
- Connection technology 2-, 3-, 4-conductor
- Typical current consumption 210 mA
- Maximum output current per channel 500 mA
- Supply voltage 24 V DC
- Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2)
- Programming languages supported Programming in acc. with IEC 61131-3
- Configuration tool Config+ Version 1.01 or later
- Realtime clock Yes
- Number of local bus devices that can be connected max. 63 (observe current consumption)
- Number of devices with parameter channel max. 24
- Number of inputs 8
- Output name Digital outputs
- Number of outputs 4
- Power dissipation max. 5 W
- Processor Altera Nios II 64 MHz
- ECLASS 11.0 27242207
- Depth 71.5 mm
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Shock 25g, Criterion 1, according to IEC 60068-2-27
- Ambient temperature (operation) -25 °C ... 55 °C
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Vibration (operation) 5g
- Mass storage 512 kByte
- Retentive mass storage 48 kByte (NVRAM)
- Program memory 512 kByte
- Number of supported devices max. 128
- Connection method Spring-cage connection
- Input name Digital inputs
- Device function PROFINET device
- Max. current consumption 870 mA (370 mA communications power + 500 mA analog voltage supply)
- Supply voltage range 19.2 V DC ... 30 V DC
- Safety function No
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical), fieldbus cable shield 1 kV
- ECLASS 4.0 27250200
- ECLASS 5.0 27242700
- ECLASS 9.0 27242207
- UNSPSC 7.0901 43201404
- Width 80 mm
- ETIM 7.0 EC000236
- UNSPSC 12.01 43201404
- UNSPSC 20.0 39122114
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2)
- Engineering tool PC WORX
- Number of control tasks 8
- Battery Integrated (rechargeable battery buffered)
- Transmission speed max. 115.2 kbps
- Description of the input EN 61131-2 type 1 NPN/PNP
- Residual ripple ± 5 %
- Controller redundancy No
- Diagnostics display No
- Interference emission Noise emission test as per EN 61000-6-4 EN 55011 Class A
- REACh SVHC 1,2-dimethoxyethane,ethylene glycol dimethyl ether (EGDME) 110-71-4
- ETIM 4.0 EC000236
- UNSPSC 6.01 43172015
- UNSPSC 11 43172018
- UNSPSC 19.0 39122114
- ETIM 6.0 EC000236
- ECLASS 4.1 27240600
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 7.0 27242207
- ETIM 3.0 EC000236
- UNSPSC 18.0 39122114
- UNSPSC 21.0 39122114
- ECLASS 5.1 27242700
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV
- ECLASS 10.0.1 27242207
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?