2700974 Phoenix Contact Programmable Logic Controllers
Part#:2700974
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
The Inline controller offers the option of communicating via PROFINET and Modbus/TCP. Programming is carried out using PC Worx Express or PC Worx (IEC 61131-3).
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2700974 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight 285 g
- Battery Integrated (rechargeable battery buffered)
- Number of devices with parameter channel max. 16
- Height 119.8 mm
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Configuration tool Config+ Version 1.01 or later
- UNSPSC 7.0901 43201404
- UNSPSC 19.0 39122114
- Width 80 mm
- Ambient temperature (operation) -25 °C ... 55 °C
- Engineering tool PC WORX
- Number of control tasks 8
- Realtime clock Yes
- Number 1
- Number of outputs 4
- Description of the input EN 61131-2 type 1 NPN/PNP
- Retentive mass storage 8 kByte (NVRAM)
- Number of supported devices max. 128
- Connection method Spring-cage connection
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical), fieldbus cable shield 1 kV
- China RoHS Environmentally Friendly Use Period = 50 years
- Depth 71.5 mm
- Connection technology 2-, 3-, 4-conductor
- Supply voltage 24 V DC
- Power dissipation max. 5 W
- Controller redundancy No
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Programming languages supported Programming in acc. with IEC 61131-3
- Shock 25g, Criterion 1, according to IEC 60068-2-27
- Diagnostics tool DIAG+
- Mass storage 256 kByte
- Number of supported branch terminals with remote bus branch max. 3
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2)
- Number of local bus devices that can be connected max. 63 (observe current consumption)
- Number of inputs 8
- Maximum output current per channel 500 mA
- Supply voltage range 19.2 V DC ... 30 V DC
- Transmission speed max. 115.2 kbps
- Degree of protection IP20
- Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2)
- Interface Parameterization/operation/diagnostics
- Input name Digital inputs
- Vibration (operation) 5g
- Program memory 256 kByte
- Amount of process data max. 4096 Bit (INTERBUS)
- Typical current consumption 210 mA
- ETIM 7.0 EC000236
- UNSPSC 13.2 39122114
- Residual ripple ± 5 %
- Safety function No
- Vibration (storage/transport) 5g
- ECLASS 5.0 27242700
- Device function PROFINET device
- Output name Digital outputs
- Max. current consumption 870 mA (370 mA communications power + 500 mA analog voltage supply)
- ETIM 4.0 EC000236
- UNSPSC 6.01 43172015
- UNSPSC 12.01 43201404
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV
- Interference emission Noise emission test as per EN 61000-6-4 EN 55011 Class A
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Processor Altera Nios II 64 MHz
- UNSPSC 20.0 39122114
- ECLASS 7.0 27242207
- ECLASS 10.0.1 27242207
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 6.0 27242200
- ECLASS 9.0 27242207
- ECLASS 5.1 27242700
- ECLASS 11.0 27242207
- ECLASS 4.0 27240400
- ETIM 3.0 EC001423
- UNSPSC 21.0 39122114
- Diagnostics display No
- ETIM 6.0 EC000236
- REACh SVHC 1,2-dimethoxyethane,ethylene glycol dimethyl ether (EGDME) 110-71-4
- UNSPSC 11 43172018
- ECLASS 4.1 27240400
- UNSPSC 18.0 39122114
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty: