Axioline F, Temperature recording module, Analog inputs: 4 (4 inputs for thermocouples or linear voltage, plus 1 input -5 V to +5 V), connection method: 2-conductor (shielded, twisted pair), transmission speed in the local bus: 100 Mbps, degree of protect
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2688598 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Power consumption typ. 1.05 W (entire device)
- Protective circuit Surge protection electronic (35 V, 0.5 s)
- Connection technology 2-conductor (shielded, twisted pair)
- A/D converter resolution 24 bit
- Input filter time 40 ms
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 10.0.1 27242601
- Description of the input Inputs for thermocouples or linear voltage
- Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- REACh SVHC Lead 7439-92-1
- ECLASS 7.0 27242601
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Measured value representation 16 bits (15 bits + sign bit)
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 6.0 27242600
- ETIM 3.0 EC001599
- Number of inputs 4 +1 mm (4 inputs for thermocouples or linear voltage, plus 1 input -5 V to +5 V)
- Measuring principle Sigma/Delta process
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Overvoltage category II (IEC 60664-1, EN 60664-1)
- Ambient temperature (operation) -25 °C ... 60 °C
- Connection method Spring-cage connection with direct connector-in method
- Conductor cross section AWG min. 24
- Net weight 144 g
- Mounting position any (no temperature derating)
- Depth 54 mm
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible max. 1.5 mm²
- Conductor cross section AWG max. 16
- Number 2
- Height 126.1 mm
- Degree of protection IP20
- Designation Supply for analog modules (UA)
- Conductor cross section solid max. 1.5 mm²
- Mounting type DIN rail
- Degree of pollution 2 (IEC 60664-1, EN 60664-1)
- UNSPSC 7.0901 43201404
- Current consumption typ. 23 mA
- ECLASS 5.0 27242201
- ECLASS 9.0 27242601
- UNSPSC 13.2 32151602
- UNSPSC 6.01 43172015
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Width 35 mm
- Conductor cross section flexible min. 0.2 mm²
- Color traffic grey A RAL 7042
- Transmission speed 100 Mbps
- Input name Analog inputs
- Supply voltage 24 V DC
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- Stripping length 8 mm
- Note on weight specifications with connectors and bus base module
- UNSPSC 11 39121311
- UNSPSC 21.0 32151602
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- ECLASS 11.0 27242601
- ECLASS 4.1 27240405
- ETIM 6.0 EC001596
- ECLASS 4.0 27240405
- ECLASS 5.1 27242601
- Sensor types (RTD) that can be used Pt 100 (2 external cold junctions, can also be used as a sensor input)
- Type of protection Short-circuit protection, overload protection of the inputs
- UNSPSC 19.0 32151602
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A for shielded cables, 2 kV
- ETIM 4.0 EC001599
- UNSPSC 12.01 39121311
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ETIM 7.0 EC001596
- UNSPSC 18.0 32151602
- UNSPSC 20.0 32151602
- Interference emission Noise emission test according to EN 61000-6-3 Class B
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?