Axioline F, Digital output module, Digital outputs: 8, 24 V DC, 2 A, connection method: 2-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2688381 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Conductor cross section flexible min. 0.5 mm²
- Color traffic grey A RAL 7042
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Connection technology 2-conductor
- Nominal output voltage 24 V DC
- Switching frequency max. 6000 per second (with nominal ohmic load, up to HW 02)
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Output current when switched off max. 300 µA
- Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- China RoHS Environmentally Friendly Use Period = 50 years
- Depth 54 mm
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Degree of protection IP20
- Conductor cross section flexible max. 1.5 mm²
- Mounting type DIN rail
- Mounting position any (no temperature derating)
- Current consumption max. 16 A (Provide external protection; if the total current of 8 A is exceeded, connect the supply at the power connector parallel via both terminal points.)
- Supply voltage 24 V DC
- Protective circuit Short-circuit protection, overload protection of the outputs electronic
- Output voltage 24 V
- Nominal load, lamp max. 48 W (at nominal voltage)
- Reverse voltage resistance to short pulses limited protection up to 0.5 A for 1 s
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Height 126.1 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- Stripping length 8 mm
- Note on weight specifications with connectors and bus base module
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Designation Supply for digital output modules (UO)
- Width 35 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Connection method Push-in connection
- Conductor cross section solid min. 0.5 mm²
- Conductor cross section AWG max. 16
- Transmission speed 100 Mbps
- Degree of pollution 2 (IEC 60664-1, EN 60664-1)
- Protection max. 16 A (polarity reversal protection up to 5 A)
- Conductor cross section solid max. 1.5 mm²
- Conductor cross section AWG min. 20
- Net weight 183.633 g
- Number of interfaces 2
- Power consumption max. 480 W (of which 3.5 W are internal losses)
- Output name Digital outputs
- Nominal load, inductive max. 48 VA (1.2 H, 12 Ω, at nominal load)
- Output voltage when switched off max. 1 V
- Behavior with inductive overload Output can be destroyed
- Behavior with overload Shutdown with automatic restart
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 11.0 27242604
- ECLASS 5.1 27242600
- ECLASS 6.0 27242600
- Load min. 10 kΩ
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- ECLASS 4.1 27240400
- ETIM 6.0 EC001599
- UNSPSC 13.2 32151602
- UNSPSC 19.0 32151602
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Overvoltage category II (IEC 60664-1, EN 60664-1)
- ECLASS 10.0.1 27242604
- ECLASS 7.0 27242604
- ETIM 4.0 EC001599
- UNSPSC 11 39121311
- UNSPSC 12.01 39121311
- Nominal load, ohmic max. 48 W (12 Ω, at nominal load)
- REACh SVHC Lead 7439-92-1
- ECLASS 5.0 27242200
- ECLASS 9.0 27242604
- ETIM 7.0 EC001599
- UNSPSC 7.0901 43201404
- UNSPSC 18.0 32151602
- UNSPSC 21.0 32151602
- Number of outputs 8
- ECLASS 4.0 27240400
- ETIM 3.0 EC001599
- UNSPSC 6.01 43172015
- UNSPSC 20.0 32151602
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?