2688349 Phoenix Contact Programmable Logic Controllers
Part#:2688349
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline F, Digital output module, Digital outputs: 16, 24 V DC, 500 mA, connection method: 1-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2688349 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 35 mm
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible max. 1.5 mm²
- Color traffic grey A RAL 7042
- Mounting position any (no temperature derating)
- Power consumption max. 240 W (of which 560 mW with internal losses)
- Number of outputs 16
- Switching frequency max. 10000 per second (with at least 50 mA load current)
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Degree of protection IP20
- Behavior with inductive overload Output can be destroyed
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 5.0 27242200
- ETIM 4.0 EC001599
- UNSPSC 11 39121311
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Conductor cross section flexible min. 0.2 mm²
- Mounting type DIN rail
- Number 2
- Current consumption max. 8 A (provide external protection)
- Nominal load, inductive 12 VA (1.2 H, 48 Ω, with nominal voltage)
- Nominal output voltage 24 V DC
- Output current when switched off max. 300 µA
- Behavior with overload Shutdown with automatic restart
- ECLASS 10.0.1 27242604
- ECLASS 5.1 27242600
- ETIM 6.0 EC001599
- ETIM 7.0 EC001599
- UNSPSC 6.01 43172015
- Depth 54 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Conductor cross section solid max. 1.5 mm²
- Conductor cross section AWG max. 16
- Supply voltage 24 V DC
- Connection technology 1-conductor
- Nominal load, lamp 12 W (at nominal voltage)
- Reverse voltage resistance to short pulses limited protection up to 0.5 A for 1 s
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27242604
- ECLASS 6.0 27242600
- UNSPSC 7.0901 43201404
- UNSPSC 19.0 32151602
- Stripping length 8 mm
- Net weight 134 g
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Output name Digital outputs
- Output voltage when switched off max. 1 V
- Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 4.1 27240400
- ECLASS 4.0 27240400
- ECLASS 7.0 27242604
- UNSPSC 13.2 32151602
- UNSPSC 20.0 32151602
- Conductor cross section AWG min. 24
- Transmission speed 100 Mbps
- Protection max. 8 A (polarity reversal protection up to 5 A)
- Output voltage 24 V
- Nominal load, ohmic 12 W (48 Ω, with nominal voltage)
- Load min. 10 kΩ
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 9.0 27242604
- ETIM 3.0 EC001599
- UNSPSC 21.0 32151602
- UNSPSC 18.0 32151602
- UNSPSC 12.01 39121311
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Designation Supply for digital output modules (UO)
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Protective circuit Short-circuit protection, overload protection of the outputs electronic
- Height 126.1 mm
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Ambient temperature (operation) -25 °C ... 60 °C
- Connection method Push-in connection
- Note on weight specifications with connectors and bus base module
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?