2688080 Phoenix Contact Programmable Logic Controllers
Part#:2688080
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline F, Analog output module, Analog outputs: 8, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2-conductor, transmission speed in the local bus: 100 Mbps, degree of protec
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2688080 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth 54 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Transmission speed 100 Mbps
- Stripping length 8 mm
- Note on weight specifications with connectors and bus base module
- Height 126.1 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Designation Supply for analog modules (UA)
- Conductor cross section flexible max. 1.5 mm²
- Conductor cross section solid min. 0.2 mm²
- Supply voltage 24 V DC
- Number of outputs 8
- Type of protection Short-circuit and overload protection
- Width 53.6 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Degree of protection IP20
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Conductor cross section solid max. 1.5 mm²
- Conductor cross section AWG max. 16
- Degree of pollution 2 (IEC 60664-1, EN 60664-1)
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Conductor cross section flexible min. 0.2 mm²
- Mounting type DIN rail
- Color traffic grey A RAL 7042
- Current consumption typ. 110 mA (8 voltage channels, 10 V output)
- Protective circuit Surge protection electronic (35 V, 0.5 s)
- Output name Analog outputs
- D/A conversion time 5 µs
- ECLASS 10.0.1 27242601
- ECLASS 4.1 27240400
- UNSPSC 6.01 43172015
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- Protective circuit/component electronic
- Process data update 300 µs
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Conductor cross section AWG min. 24
- Net weight 260 g
- Mounting position any (no temperature derating)
- Number 2
- Power consumption typ. 1.725 W (to UBus and UA; power input; no load, output 0 V)
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 5.1 27242600
- ETIM 3.0 EC001599
- ECLASS 7.0 27242601
- UNSPSC 7.0901 43201404
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Connection method Push-in connection
- Connection technology 2-conductor
- Load/output load current output to 500 Ω
- Representation of output values 16 bits (15 bits + sign)
- Load/output load voltage output > 2 kΩ
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Voltage output signal 0 V ... 5 V
- Permissible cable length max. 250 m (Reference cable type LiYCY (TP) n*2*0.5 mm²)
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- China RoHS Environmentally Friendly Use Period = 50 years
- REACh SVHC Lead 7439-92-1
- ECLASS 4.0 27240400
- ETIM 6.0 EC001596
- D/A converter resolution 16 bit
- Note regarding the connection technology shielded, twisted pair
- Data formats IB IL, S7-compatible
- ECLASS 9.0 27242601
- UNSPSC 12.01 39121311
- UNSPSC 11 39121311
- Overvoltage category II (IEC 60664-1, EN 60664-1)
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 11.0 27242601
- Current output signal 0 mA ... 20 mA
- Precision typ. 0.1 % (of output range final value)
- Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
- ECLASS 5.0 27242200
- ECLASS 6.0 27242600
- ETIM 7.0 EC001596
- UNSPSC 21.0 32151602
- UNSPSC 18.0 32151602
- UNSPSC 19.0 32151602
- ETIM 4.0 EC001599
- UNSPSC 20.0 32151602
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 up to HW 03: Criterion B,DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables
- UNSPSC 13.2 32151602
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty