Axioline F, Temperature recording module, Analog inputs: 8 (for resistance temperature detectors), connection method: 2-, 3-, 4-conductor (shielded), transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2688077 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Caption Dimensional drawing
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Stripping length 8 mm
- Mounting position any (no temperature derating)
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- Current consumption typ. 15 mA
- Protective circuit Surge protection electronic (35 V, 0.5 s)
- A/D converter resolution 24 bit
- Measured value representation 16 bits (15 bits + sign bit)
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- Depth 54 mm
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000Â m above sea level)
- Conductor cross section solid max. 1.5 mm²
- Color traffic grey A RAL 7042
- Ambient temperature (operation) -25 °C ... 60 °C
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible max. 1.5 mm²
- Conductor cross section AWG max. 16
- Number 2
- Width 53.6 mm
- Note on dimensions The depth is valid when a THÂ 35-7,5 DIN rail is used (according to ENÂ 60715).
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000Â m above sea level)
- Degree of protection IP20
- Designation Supply for analog modules (UA)
- Height 126.1 mm
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Connection method Push-in connection
- Conductor cross section flexible min. 0.2 mm²
- Net weight 241.3 g
- Transmission speed 100 Mbps
- Number of inputs 8 (for resistance temperature detectors)
- Note on weight specifications with connectors and bus base module
- Supply voltage range 19.2 VÂ DC ... 30 VÂ DC (including all tolerances, including ripple)
- Nominal value of the current sources 1 mA (Pt 100, Ni 100, RLin 500 Ω; pulse current, the specification is valid during the sampling phase)
- Sensor types (RTD) that can be used Pt, Ni, KTY, Cu sensors
- Type of protection Short-circuit protection, overload protection of the inputs
- Conductor cross section AWG min. 24
- Power consumption typ. 0.94 W (at UBus and UA)
- Input name Analog inputs
- Data formats IB IL, S7-compatible
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 4.1 27240400
- ETIM 4.0 EC001599
- UNSPSC 13.2 32151602
- UNSPSC 18.0 32151602
- Connection technology 2-, 3-, 4-conductor (shielded)
- Input filter time 40 ms
- Linear resistance measuring range 0 Ω ... 500 Ω
- Test section 5Â V supply of the local bus (UBus) / 24Â V supply (I/Os) 500 VÂ AC 50 Hz 1 min.
- Protection class III (IECÂ 61140, ENÂ 61140, VDEÂ 0140-1)
- ECLASS 11.0 27242601
- ECLASS 5.1 27242600
- ETIM 3.0 EC001599
- UNSPSC 11 39121311
- UNSPSC 7.0901 43201404
- Mounting type DIN rail
- Supply voltage 24 VÂ DC
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) ENÂ 61000-4-2/IECÂ 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields ENÂ 61000-4-3/IECÂ 61000-4-3 Criterion A, Field intensity: 10 V/m
- REACh SVHC Lead 7439-92-1
- ECLASS 10.0.1 27242601
- ECLASS 6.0 27242600
- ECLASS 9.0 27242601
- ETIM 7.0 EC001596
- UNSPSC 20.0 32151602
- Degree of pollution 2 (IECÂ 60664-1, ENÂ 60664-1)
- Description of the input Inputs for resistive temperature sensors
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) ENÂ 61000-4-4/IECÂ 61000-4-4 Criterion B, 2Â kV
- Mechanical tests Vibration resistance in acc. with ENÂ 60068-2-6/IECÂ 60068-2-6 5g
- ECLASS 5.0 27242200
- ETIM 6.0 EC001596
- UNSPSC 12.01 39121311
- UNSPSC 19.0 32151602
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference ENÂ 61000-4-6/IECÂ 61000-4-6 Criterion A, Test voltage 10 V
- Overvoltage category II (IECÂ 60664-1, ENÂ 60664-1)
- ECLASS 4.0 27240400
- ECLASS 7.0 27242601
- UNSPSC 6.01 43172015
- UNSPSC 21.0 32151602
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?