2404267 Phoenix Contact Programmable Logic Controllers

2404267 on Power Resource International
Phoenix Contact

Part#:2404267

Manufacturer:Phoenix Contact

Category:Programmable Logic Controllers

Product Lifecycle:Active

Get a quick Quote!

PLCnext Control for the direct control of Axioline F I/Os. With two Ethernet interfaces. Complete with connector and bus base module.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2404267 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Weight
    225.6 g
  • Air pressure (storage/transport)
    58 kPa ... 106 kPa (up to 4500 m above mean sea level)
  • Engineering tool
    PLCnext Engineer
  • Retentive mass storage
    48 kByte (NVRAM)
  • Programming languages supported
    Programming in acc. with IEC 61131-3
  • Mass storage
    16 Mbyte
  • Number of supported devices
    max. 63 (per station)
  • Typical current consumption
    typ. 200 mA (without I/Os and UL = 24 V)
  • ETIM 4.0
    EC001435
  • Degree of protection
    IP20
  • Supports cloud computing
    yes
  • Operating system
    Linux
  • Amount of process data
    max. 16384 Bit (per station)
  • Protocols supported
    HTTP
  • ETIM 6.0
    EC000236
  • RAM
    512 Mbyte DDR3 SDRAM
  • Accuracy realtime clock
    1.73 s/day = 20 ppm at 25 °C
  • Width
    45 mm
  • IoT platform
    PROFICLOUD
  • Number of local bus devices that can be connected
    max. 63 (observe current consumption)
  • Number
    2
  • Interface
    Ethernet
  • ECLASS 7.0
    27242207
  • ECLASS 9.0
    27242207
  • Processor
    Arm® Cortex®-A9 2x 800 MHz
  • Program memory
    8 Mbyte
  • Realtime clock
    Yes
  • Connection method
    RJ45 jack
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • Shock (operation)
    10g (Bump endurance test according to DIN EN 60068-2-27)
  • ECLASS 4.0
    27240602
  • ECLASS 5.1
    27242700
  • ETIM 7.0
    EC000236
  • ECLASS 6.0
    27242200
  • ETIM 3.0
    EC001045
  • Height
    126.93 mm
  • Diagnostics display
    No
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Permissible humidity (operation)
    5 % ... 95 % (according to DIN EN 61131-2)
  • Safety function
    No
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • Depth
    75 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Note on controller redundancy
    applicative system redundancy possible
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
  • Ambient temperature (operation)
    -25 °C ... 60 °C up to 2000 m above mean sea level (observe derating)
  • Shock
    30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
  • Device function
    PROFINET controller, PROFINET device
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • Transmission speed
    10/100 Mbps (full duplex)
  • Update rate
    min. 1 ms (4 devices)
  • Permissible humidity (storage/transport)
    5 % ... 95 % (according to DIN EN 61131-2)
  • Vibration (operation)
    5g
  • Interference emission
    Noise emission test as per EN 61000-6-4
  • Controller redundancy
    yes
  • Power dissipation
    max. 10.6 W
  • Max. current consumption
    442 mA
  • Vibration (storage/transport)
    5g
  • Supply voltage
    24 V DC
  • Residual ripple
    ± 5 %
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • ECLASS 10.0.1
    27242207
  • ECLASS 11.0
    27242207
  • ECLASS 4.1
    27240602
  • Specification
    Version 2.3
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.0
    27242700
  • Supply voltage range
    19.2 V DC ... 30 V DC
  • REACh SVHC
    Lead 7439-92-1

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

Relevant products

What can I help you find today?

Recommended parts