2320924 Phoenix Contact AC/DC Power Supplies

2320924 on Power Resource International
Phoenix Contact

Part#:2320924

Manufacturer:Phoenix Contact

Category:AC/DC Power Supplies

Product Lifecycle:Active

Get a quick Quote!

Primary-switched power supply unit, QUINT POWER, Screw connection, SFB Technology (Selective Fuse Breaking), input: 3-phase, output: 24 V DC / 20 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2320924 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • ECLASS 7.0
    27049002
  • ETIM 6.0
    EC002540
  • UNSPSC 12.01
    39121004
  • UNSPSC 21.0
    39121004
  • Height
    130 mm
  • Depth
    125 mm
  • Depth with alternative assembly
    72 mm
  • Degree of protection
    IP20
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Installation height
    5000 m
  • Nominal input voltage range
    3x 400 V AC ... 500 V AC
  • AC frequency range
    45 Hz ... 65 Hz
  • Frequency range DC
    0 Hz
  • Nominal power consumption
    783 VA
  • Inrush current
    < 20 A (typical)
  • Type of protection
    Transient surge protection
  • Setting range of the output voltage (USet)
    18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
  • POWER BOOST (IBoost)
    26 A (-25 °C ... 40 °C permanent, UOUT = 24 V DC )
  • Derating
    60 °C ... 70 °C (2.5%/K)
  • Connection in series
    yes
  • Residual ripple
    < 40 mVPP (with nominal values)
  • Typical response time
    < 0.16 s
  • Peak switching voltages nominal load
    < 40 mVPP (at nominal values, 20 MHz)
  • Power loss nominal load max.
    40 W
  • Efficiency
    > 93 % (at 400 V AC and nominal values)
  • Insulation voltage input/output
    4 kV AC (type test)
  • Insulation voltage output / PE
    500 V DC (routine test)
  • Conductor cross section solid max.
    6 mm²
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section AWG max.
    10
  • Screw thread
    M4
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Width
    69 mm
  • Width with alternative assembly
    125 mm
  • Height with alternative assembly
    130 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Ambient temperature (operation)
    -40 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Ambient temperature (start-up type tested)
    -40 °C
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Degree of pollution
    2
  • Input voltage range
    3x 320 V AC ... 575 V AC
  • Discharge current to PE
    < 3.5 mA
  • Current consumption
    3x 1.6 A (400 V AC)
  • Recommended breaker for input protection
    6 A ... 16 A (AC: Characteristics B, C, D, K)
  • Nominal output voltage
    24 V DC ±1 %
  • Mains buffering time
    typ. 28 ms (400 V AC)
  • Selective Fuse Breaking (ISFB)
    120 A (12 ms)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Feedback voltage resistance
    max. 32 V DC
  • Protection against overvoltage at the output (OVP)
    < 32 V DC
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Output power
    480 W
  • Maximum power dissipation in no-load condition
    11 W
  • UNSPSC 18.0
    39121004
  • UNSPSC 13.2
    39121004
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • Protection class
    I
  • Insulation voltage input / PE
    3.5 kV AC (type test)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Connection method
    Screw connection
  • Housing material
    Steel sheet, zinc-plated
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section AWG min.
    18
  • EMC requirements for noise emission
    EN 61000-6-3
  • Stripping length
    7 mm
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment
    EN 50178
  • Rail applications
    EN 50121-4
  • UL approvals
    UL/C-UL listed UL 508
  • CSA
    CAN/CSA-C22.2 No. 60950-1-07
  • Contact discharge
    8 kV (Test Level 4)
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Standard - Equipment safety
    BG (design tested)
  • Mains variation/undervoltage
    SEMI F47-0706 Compliance Certificate
  • Shipbuilding approval
    DNV GL (EMC B), ABS, LR, RINA, NK, BV
  • ECLASS 10.0.1
    27040701
  • Protective circuit/component
    Varistor, gas-filled surge arrester
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Test field strength
    10 V/m (Test Level 3)
  • Output
    1 kV (Test Level 2 - symmetrical)
  • I/O/S
    asymmetrical
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 11.0
    27040701
  • ETIM 3.0
    EC001039
  • Nominal output current (IN)
    20 A (-25 °C ... 60 °C, UOUT = 24 V DC)
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Conducted interference
    EN 61000-4-6
  • Voltage
    10 V (Test Level 3)
  • ECLASS 4.0
    27040700
  • ECLASS 6.0
    27049000
  • ETIM 4.0
    EC000599
  • UNSPSC 11
    39121004
  • Net weight
    1.5 kg
  • Discharge in air
    15 kV (Test Level 4)
  • Comments
    Criterion A
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Criterion A
    Normal operating behavior within the specified limits.
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 4.1
    27040700
  • ECLASS 5.1
    27049000
  • ETIM 7.0
    EC002540
  • UNSPSC 20.0
    39121004
  • Installation distance right/left
    5 mm / 5 mm
  • Max. permissible relative humidity (operation)
    100 % (at 25 °C, non-condensing)
  • MTBF (IEC 61709, SN 29500)
    > 900000 h (25 °C)
  • Electromagnetic HF field
    EN 61000-4-3
  • Input
    3 kV (Test Level 3 - symmetrical)
  • Surge voltage load (surge)
    EN 61000-4-5
  • ECLASS 9.0
    27040701
  • UNSPSC 7.0901
    39121004
  • UNSPSC 19.0
    39121004
  • Electrostatic discharge
    EN 61000-4-2
  • Frequency range
    0.15 MHz ... 80 MHz
  • Fast transients (burst)
    EN 61000-4-4
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 5.0
    27049000
  • UNSPSC 6.01
    30211502

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?