Primary-switched DIN rail power supply unit. AC input: suitable for operation between two phases (400 V AC). DC input: suitable for operation in an FI intermediate circuit. Output: 24 V DC/20 A.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2320830 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Width
    120 mm
  • Depth
    125 mm
  • Degree of protection
    IP20
  • Installation height
    ≤ 2000 m
  • Height
    130 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Degree of pollution
    2
  • AC frequency range
    45 Hz ... 65 Hz
  • Mains buffering time
    typ. 20 ms (400 V AC)
  • Recommended breaker for input protection
    10 A ... 16 A (Characteristic B, C)
  • Selective Fuse Breaking (ISFB)
    120 A (20 ms)
  • POWER BOOST (IBoost)
    26 A (-25 °C ... 40 °C permanent, UOUT = 24 V DC )
  • Max. capacitive load
    unlimited
  • Maximum power dissipation in no-load condition
    11 W
  • Efficiency
    > 92 % (600 V DC)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Connection method
    Screw connection
  • Conductor cross section AWG max.
    10
  • Standard - Electrical safety
    EN 60950-1/VDE 0805 (SELV)
  • Rail applications
    EN 50121-4
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • ECLASS 5.1
    27049000
  • ECLASS 9.0
    27040701
  • ETIM 7.0
    EC002540
  • UNSPSC 11
    39121004
  • UNSPSC 20.0
    39121004
  • Installation distance top/bottom
    50 mm / 50 mm
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Input voltage range
    2x 360 V AC ... 575 V AC
  • Current consumption
    2.5 A (400 V AC)
  • Type of protection
    Transient surge protection
  • Nominal output current (IN)
    20 A (-25 °C ... 60 °C)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Protection against overvoltage at the output (OVP)
    < 35 V DC
  • Feedback voltage resistance
    < 35 V DC
  • Active current limitation
    Approx. 27 A
  • Insulation voltage input/output
    1.5 kV AC (type test)
  • Insulation voltage input / PE
    4 kV AC (type test)
  • Insulation voltage output / PE
    500 V DC (routine test)
  • Conductor cross section solid max.
    6 mm²
  • Stripping length
    8 mm
  • Screw thread
    M3
  • Standard - Safe isolation
    DIN VDE 0100-410
  • ECLASS 4.0
    27040700
  • ECLASS 5.0
    27049000
  • ECLASS 7.0
    27049002
  • ETIM 4.0
    EC002540
  • UNSPSC 7.0901
    39121004
  • UNSPSC 21.0
    39121004
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Installation distance right/left
    5 mm / 5 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Frequency range DC
    0 Hz
  • Input fuse
    3.15 A (slow-blow, internal)
  • Protective circuit/component
    Varistor
  • Setting range of the output voltage (USet)
    18 V DC ... 29.5 V DC (UIN ≥ 360 V AC / 480 V DC)
  • Connection in series
    yes
  • Residual ripple
    < 50 mVPP (with nominal values)
  • Output power
    480 W
  • Peak switching voltages nominal load
    < 50 mVPP (20 MHz)
  • Protection class
    I
  • Housing material
    Steel sheet, zinc-plated
  • Conductor cross section AWG min.
    24
  • Standard - Safety of transformers
    EN 61558-2-17
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • UL approvals
    UL/C-UL listed UL 508
  • ECLASS 11.0
    27040701
  • ECLASS 6.0
    27049000
  • ETIM 3.0
    EC001039
  • UNSPSC 12.01
    39121004
  • UNSPSC 18.0
    39121004
  • Nominal input voltage range
    2x 400 V AC ... 500 V AC
  • Nominal power consumption
    888 VA
  • Inrush current
    < 85 A (typical)
  • Nominal output voltage
    24 V DC ±1 %
  • Derating
    60 °C ... 70 °C (2.5%/K)
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Power loss nominal load max.
    51 W
  • Net weight
    2 kg
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section flexible max.
    4 mm²
  • ECLASS 10.0.1
    27040701
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27040700
  • ETIM 6.0
    EC002540
  • UNSPSC 6.01
    30211502
  • UNSPSC 19.0
    39121004
  • UNSPSC 13.2
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?