2320283 Phoenix Contact UPS (DC)
Part#:2320283
Manufacturer:Phoenix Contact
Category:UPS (DC)
Product Lifecycle:Active
Get a quick Quote!
Uninterruptible power supply with IQ technology for DIN rail mounting. Input: 120/230 V AC, output: 120/230 V AC/1 kVA. Provides information regarding the state of charge, remaining runtime, and service life of the rechargeable battery module at any time,
About the manufacturer: Phoenix Contact is one of the manufacturers that offers UPS (DC) that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2320283 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 130 mm
- Installation distance top/bottom 50 mm / 50 mm
- Climatic class 3K3 (EN 60721)
- Nominal input voltage 100 V AC -10 % / +20 %
- Installation distance right/left 5 mm / 5 mm
- Ambient temperature (operation) -25 °C ... 60 °C (> 50 °C: 2,5 % / K)
- Installation height ≤ 3000 m (> 2000 m: 0,6 % / 100 m)
- Power factor (cos phi) 0.9
- Net weight 5 kg
- Efficiency > 92 % (120 V AC)
- Conductor cross section flexible min. 0.2 mm²
- Standards/regulations EN 62040-1
- Discharge in air ± 8 kV
- Degree of protection IP20
- Buffer period 1 h (38 AH)
- POWER BOOST (IBoost) 13 A (120 V AC)
- Connection method Screw connection
- Conductor cross section AWG min. 30
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Frequency range 0.15 MHz ... 80 MHz
- Conducted interference EN 61000-4-6
- Power frequency magnetic field EN 61000-4-8
- ECLASS 9.0 27040705
- Contact discharge ± 6 kV
- Input ± 2 kV
- Depth 125 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Input voltage range 90 V AC ... 264 V AC
- Nominal output voltage 100 V AC
- Conductor cross section solid min. 0.2 mm²
- Standard designation Uninterruptible power supply systems
- Surge voltage load (surge) EN 61000-4-5
- ECLASS 11.0 27040705
- ECLASS 6.0 27040600
- Width 290 mm
- Max. permissible relative humidity (operation) ≤ 95 %
- AC frequency range 45 Hz ... 65 Hz
- Nominal output current (IN) 7.8 A (100 V AC)
- Maximum power dissipation in no-load condition typ. 17 W (120 V AC)
- MTBF (IEC 61709, SN 29500) 217546 h (230 V AC, at 40 °C)
- Protection class I
- Conductor cross section AWG max. 12
- Stripping length 8 mm
- Electrostatic discharge EN 61000-4-2
- Electromagnetic HF field EN 61000-4-3
- Voltage 10 V
- Output ± 2 kV
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 7.0 27040602
- Permissible backup fuse B16 230 V AC
- Conductor cross section flexible max. 2.5 mm²
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Connection in parallel Yes, 2
- Conductor cross section solid max. 2.5 mm²
- Test field strength 100 A/m
- Signal 1 kV (asymmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 5.1 27040603
- Connection in series No
- Fast transients (burst) EN 61000-4-4
- ECLASS 10.0.1 27040705
- ETIM 6.0 EC000382
- Comments Criterion A
- Frequency 50 Hz
- ETIM 7.0 EC000382
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?