2320212 Phoenix Contact UPS (DC)

2320212 on Power Resource International
Phoenix Contact

Part#:2320212

Manufacturer:Phoenix Contact

Category:UPS (DC)

Product Lifecycle:Active

Get a quick Quote!

Uninterruptible power supply with IQ technology for DIN rail mounting, input: 24 V DC, output: 24 V DC/5 A, including mounted universal DIN rail adapter UTA 107/30

About the manufacturer: Phoenix Contact is one of the manufacturers that offers UPS (DC) that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2320212 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Depth
    125 mm
  • Installation distance right/left
    5 mm / 5 mm
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Current consumption (charging process)
    1.8 A (Charging, mains operation)
  • POWER BOOST (IBoost)
    7.5 A (-25°C ... 40°C)
  • Selective Fuse Breaking (ISFB)
    32.5 A (-25 °C ... 60 °C)
  • Conductor cross section flexible min.
    0.2 mm²
  • EMC requirements for noise immunity
    EN 61000-6-1
  • UL approvals
    UL Listed UL 508
  • Height
    130 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C
  • Current consumption (maximum)
    9.4 A (maximum, mains operation)
  • Output voltage range (depends on the input voltage)
    19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0,5 V DC)
  • Net weight
    0.5 kg
  • Connection method
    Pluggable screw connection
  • Conductor cross section AWG min.
    24
  • EMC requirements for noise emission
    EN 61000-6-3
  • ECLASS 11.0
    27040705
  • Input voltage
    24 V DC
  • Nominal output voltage
    24 V DC
  • Efficiency
    > 98 % (Mains operation, with charged energy storage)
  • Conductor cross section solid min.
    0.2 mm²
  • Screw thread
    M4
  • Standard - Electrical safety
    EN 60950-1/VDE 0805 (SELV)
  • Electrostatic discharge
    EN 61000-4-2
  • Fixed backup threshold
    ≤ 22 V DC
  • Nominal input voltage
    24 V DC
  • IQ technology
    Yes
  • Protection class
    III
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section AWG max.
    12
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Degree of protection
    IP20
  • Variable connect threshold
    1 V/0.1 s
  • Nominal output current (IN)
    5 A (-25 °C ... 60 °C)
  • Assembly instructions
    alignable: horizontal 5 mm, vertical 50 mm
  • Conductor cross section flexible max.
    2.5 mm²
  • Rail applications
    EN 50121-4
  • Discharge in air
    15 kV (Test Level 4)
  • Fast transients (burst)
    EN 61000-4-4
  • Input voltage range
    18 V DC ... 30 V DC
  • MTBF (IEC 61709, SN 29500)
    > 500000 h (25 °C)
  • Electromagnetic HF field
    EN 61000-4-3
  • Surge voltage load (surge)
    EN 61000-4-5
  • Criterion A
    Normal operating behavior within the specified limits.
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 6.0
    27040600
  • ETIM 4.0
    EC000382
  • ETIM 7.0
    EC000382
  • UNSPSC 11
    39121011
  • UNSPSC 20.0
    39121011
  • Width with alternative assembly
    123 mm
  • Test field strength
    3 V/m
  • Comments
    Criterion A
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 5.1
    27040600
  • ECLASS 9.0
    27040705
  • ECLASS 7.0
    27040603
  • UNSPSC 13.2
    39121011
  • UNSPSC 18.0
    39121011
  • UNSPSC 21.0
    39121011
  • Height with alternative assembly
    130 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Width
    35 mm
  • Depth with alternative assembly
    39 mm
  • Max. permissible relative humidity (operation)
    ≤ 95 % (25 °C, non-condensing)
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Input
    1 kV (Test Level 2 - symmetrical)
  • Output
    1 kV (Test Level 2 - symmetrical)
  • Voltage
    10 V (Test Level 3)
  • ECLASS 4.0
    27040600
  • ECLASS 5.0
    27040600
  • ECLASS 4.1
    27040600
  • UNSPSC 6.01
    30211510
  • UNSPSC 19.0
    39121011
  • Stripping length
    7 mm
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Contact discharge
    8 kV (Test Level 4)
  • Frequency range
    0.15 MHz ... 80 MHz
  • I/O/S
    asymmetrical
  • Conducted interference
    EN 61000-4-6
  • ECLASS 10.0.1
    27040705
  • REACh SVHC
    Lead 7439-92-1
  • ETIM 3.0
    EC001039
  • ETIM 6.0
    EC000382
  • UNSPSC 7.0901
    39121011
  • UNSPSC 12.01
    39121011

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes